LEDs are connected to control and supply outputs in a way presented in the figure. On 
every line there can be a defined amount of light, which depends on the received power 
and the loadability of every line is max. 500mA. Therefore with all receivers connected 
sum up all lines and select a feeder of an appropriate power. 

CAUTION!  

Current loadability of a single connection shall not exceed 10A!!! 

In order to increase the current loadability of the power supply joint attach power supply 
leads parallel to a number of proper inputs (e.g. to attach 2 wires to one pin) to increase the 
permissible current.  The driver is provided with 2 power supply inputs - one for the first 
24 channels and the second for channels 24 - 48. Connect these to one feeder or to two 
feeders. 

At the last driver in the DMX 

line install a terminator

 

Содержание PLD48

Страница 1: ...Instruction for use PLD48 PIXEL DMX LED Driver...

Страница 2: ...ct We have made every effort to ensure a highest quality of our products to meet your expectations Should you have any comments please let us know We will be grateful for all suggestions to help us to...

Страница 3: ...neral description 4 2 Basic safety conditions 4 3 Description of the device 5 4 Connections plan 6 5 Setting the DIP SW DMX mode Stand Alone Mode 7 5 1 DMX mode 7 5 2 Stand alone mode 7 6 Maintenance...

Страница 4: ...of possible assembly mistakes A large 9 bit control definition and dimming characteristics adapted to the human eye sensitivity causes the lighting intensity to change in a linear and infinitely vari...

Страница 5: ...t GND 12V and DMX signal joint 2 Output joints channels 1 18 3 Output joints channels 19 30 4 Output joints channels 31 48 5 Supply power indicator light 6 DMX512 signal presence indicator light 7 DIP...

Страница 6: ...d select a feeder of an appropriate power CAUTION Current loadability of a single connection shall not exceed 10A In order to increase the current loadability of the power supply joint attach power su...

Страница 7: ...th a proper control signal the DMX OK control light blinks with a 0 5 HZ frequency If the signal is not proper the control light is out See below for an example of the DMX address setting 5 2 Stand al...

Страница 8: ...n report to the seller or manufacturer Caution All single handed repairs can cause irreparable damages or some threats 7 Technical parameters DMX channels 512 Power supply 12 VDC Power consumption 24A...

Отзывы: