background image

TABLE 2: Load v Span.

USER INSTRUCTIONS

MOD 70

Recommended top sling types: Textile slings, wire rope slings with soft eyes and chain slings with small end fittings.

If thimble eyes are used with wire rope slings, make sure sling angle is 30 degrees or less. 

Other types exist but not all are suitable due to end fitting size, particularly larger capacity chain hook and thimble eyes.

Note: Lengthening the slings can give greater clearance. 

Refer to Modulift supplier if in doubt.

ASSEMBLY PROCEDURE.

 

Check the ID plates on each Modulift component to ensure the correct size is used. 

Lay out the Struts and End Units in the correct configuration (see table 2), laid on flats to prevent rolling.

Check that all pairs of flanges are clear from debris, sand etc. before connection.

Bolt the components together using bolts, nuts & washers provided. Tighten the bolts to a torque as shown overleaf, 6 

bolts per connection*. 

Place drop link inside the jaw of an end unit, with the larger hole of drop link lined up with the End Unit hole.

Place a top sling onto the body of a top shackle, and put jaw of top shackle over the end unit jaw.

Put top shackle pin through shackle, end unit jaw and drop link, and repeat for other spreader beam end.

Attach free ends of top slings to crane hook.

Attach lower slings and shackles to lower holes of drop links, and attach them to the load to be lifted.

The assembled spreader beam and lifting rig must be thoroughly checked

by a competent person prior to lifting.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

• 

Max number of struts allowed in spreader         

   assembly: 5

• 

Assemble longer struts in the centre of the     

   spreader configuration

• 

Sling angle is crucial to safe use of spreader

The rigger must ensure that 

there is a clearance between the 

sling end fitting and the end unit 

as shown.

CLEARANCE

CLEARANCE

Span 

/m

SWL

/ t

Min Top 

Sling

Length /m

Span 

/m

SWL

/ t

Min  Top 

Sling

Length / m

1

70

0.7

EU

EU

1

70

1

1.5

70

1.1

EU

0.5

EU

1.5

70

1.5

2

70

1.5

EU

1

EU

2

70

2

2.5

70

1.8

EU

1

0.5

EU

2.5

70

2.5

3

70

2.2

EU

2

EU

3

70

3

3.5

70

2.5

EU

2

0.5

EU

3.5

70

3.5

4

70

2.9

EU

2

1

EU

4

70

4

4.5

70

3.2

EU

0.5

2

1

EU

4.5

70

4.5

5

70

3.6

EU

4

EU

5

70

5

5.5

70

3.9

EU

4

0.5

EU

5.5

70

5.5

6

70

4.3

EU

4

1

EU

6

70

6

6.5

70

4.6

EU

0.5

4

1

EU

6.5

70

6.5

7

70

5.0

EU

4

2

EU

7

70

7

7.5

67

5.3

EU

0.5

4

2

EU

7.5

70

7.5

8

58

5.7

EU

1

4

2

EU

8

70

8

8.5

51

6.0

EU

0.5

1

4

2

EU

8.5

70

8.5

9

44

6.4

EU

4

4

EU

9

70

9

9.5

39

6.8

EU

4

4

0.5

EU

9.5

68

9.5

10

34

7.1

EU

4

4

1

EU

10

59

10

10.5

30

7.5

EU

1

4

4

0.5

EU

10.5

53

10.5

11

27

7.8

EU

2

4

4

EU

11

47

11

11.5

25

8.2

EU

2

4

4

0.5

EU

11.5

43

11.5

12

22

8.5

EU

2

4

4

1

EU

12

38

12

45˚ STV

30˚ STV

Recommended

Configuration

EU - End Unit (0.5m)

STV = ‘SLING TO 

VERTICAL’

 

ANGLE,  ß

DO’s & DON’TS

•  Do ensure to load the spreader through the drop links only. i.e. adhere to Fig. 1.

•  Do keep the loaded spreader clear of obstacles - any contact could cause beam failure.

•  Do ensure correct use of appropriate top slings, do not twist any slings unnecessarily.

•  Do not hang any load from the spreader tube or flanges.

•  Do not exceed stated SWL for that particular span - adhere to table 2.

•  Do not rig the lower slings more than 6 degrees from vertical.

•  When moving or positioning long struts or assemblies use tag lines to control movement.

•  Individual components can be heavy and extreme care must be taken if manual handling.

*The number and grade of bolts is critical for the safe use of the spreader particularly at longer spans

Tel: 0808 123 69 69 
Fax: 0117 9381 602 
Email: [email protected]