![Modul-Connect DC-DC 30A Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/modul-connect/dc-dc-30a/dc-dc-30a_owners-manual_1818245008.webp)
8
• The 1mm² ignition positive (+)
(brown) cable can be extended
beyond 4 meters by the same 1mm²
cable, as this cable draws very little
load.
Modul-Connect Battery Charger
Installation:
• Choose an appropriate mounting
location.
• All fuses, fuse holders and
connecting cables are supplied with
the product.
• This battery charger shall be
mounted and connected as close to
the auxiliary battery (which is being
charged) as possible.
• The battery charger has to be
securely mounted on a metal or
non-combustible surface.
• Use a mounting template to mark
the positions of the mounting screws.
• The battery charger has 4 off fixing
holes (6.5mm diameter) and 4 off
fixing slots (6mm x 10mm) for ease
of mounting.
• It is recommended to use a minimum
of 4 off M5 fixings to secure the
battery charger.
• Drill the 4 mounting holes, place the
charger in position and fasten it to
the mounting surface.
IMPORTANT:
Connection Procedure / Power up
sequence to ensure normal operations:
1. Remove all fuses from the fuse
holders.
2. Connect the auxiliary battery
positive cable (white) to the charger
output via a 40A fuse holder.
3. Connect the charger negative cable
(black) to the battery negative or
chassis earth.
4. Connect the charger input cable
(red) to the starter battery via a 40A
fuse holder.
5. Connect the positive remote input
cable (brown) to the ignition supply
using supplied cables and fuse
holder.
6. Insert 40A auxiliary battery fuse.
7. Insert 40A starter battery fuse.
8. Insert the 1A fuse into the ignition
feed.
If this order is not followed the unit may
flash amber for up to 10 minutes at key
on (even if the auxiliary battery is fully
charged).
After the elapsed time the Modul-
Connect Battery Charger will resume
normal function.