Modul-Connect DC-DC 30A Скачать руководство пользователя страница 8

8

•  The 1mm² ignition positive (+) 

(brown) cable can be extended 
beyond 4 meters by the same 1mm² 
cable, as this cable draws very little 
load.

Modul-Connect Battery Charger 
Installation:

•  Choose an appropriate mounting 

location. 

•  All fuses, fuse holders and 

connecting cables are supplied with 
the product.

•  This battery charger shall be 

mounted and connected as close to 
the auxiliary battery (which is being 
charged) as possible. 

•  The battery charger has to be 

securely mounted on a metal or 
non-combustible surface.

•  Use a mounting template to mark 

the positions of the mounting screws.

•  The battery charger has 4 off fixing 

holes (6.5mm diameter) and 4 off 
fixing slots (6mm x 10mm) for ease 
of mounting.

•  It is recommended to use a minimum 

of 4 off M5 fixings to secure the 
battery charger.

•  Drill the 4 mounting holes, place the 

charger in position and fasten it to 
the mounting surface. 

IMPORTANT: 

Connection Procedure / Power up 
sequence to ensure normal operations:

1.  Remove all fuses from the fuse 

holders.

2.  Connect the auxiliary battery 

positive cable (white) to the charger 
output via a 40A fuse holder.

3.  Connect the charger negative cable 

(black) to the battery negative or 
chassis earth.

4.  Connect the charger input cable 

(red) to the starter battery via a 40A 
fuse holder.

5.  Connect the positive remote input 

cable (brown) to the ignition supply 
using supplied cables and fuse 
holder.

6.   Insert 40A auxiliary battery fuse.

7.  Insert 40A starter battery fuse.

8.  Insert the 1A fuse into the ignition 

feed.

If this order is not followed the unit may 
flash amber for up to 10 minutes at key 
on (even if the auxiliary battery is fully 
charged).

After the elapsed time the Modul-
Connect Battery Charger will resume 
normal function.

Содержание DC-DC 30A

Страница 1: ...Modul Connect BATTERY CHARGER DC DC 30A Owner s Manual Document Part Number MSDCDC Rev 1 03 17 Service Contact Information E mail info modul system com Phone 46 31 746 87 00 Web www modul system com...

Страница 2: ...OR FUTURE REFERENCE DISCLAIMER While every precaution has been taken to ensure the accuracy of the contents of this manual Modul System assumes no responsibility for errors or omissions Note as well t...

Страница 3: ...o not cover or obstruct any air vent openings and or install in a zero clearance compartment WARNING FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR SERIOUS INJURY When working with electr...

Страница 4: ...rosion in your eyes Avoid touching eyes while working near battery In very cold weather a discharged battery may freeze NEVER charge a frozen battery Gases may form cracking the case and spray out bat...

Страница 5: ...nstallation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the...

Страница 6: ...lt in personal injury or loss of life 3 1 UNDERSTANDING THE UNIT FEATURES Led Status Indicator Display Connection cables AC Output Front Panel 3 INSTALLATION CAUTION Before beginning your installation...

Страница 7: ...C Input Output and ignition positive cables Use of low resistance wire is required for all the DC connections between the battery charger and the battery bank The battery charger is supplied with inpu...

Страница 8: ...e the battery charger Drill the 4 mounting holes place the charger in position and fasten it to the mounting surface IMPORTANT Connection Procedure Power up sequence to ensure normal operations 1 Remo...

Страница 9: ...gnition circuit without cutting into any cables on the vehicle The mini blade ignition jumper has two circuit slots on one side and a fuse plug on the other When plugged into one of the vehicle s circ...

Страница 10: ...pen fuse box and remove selected fuse 3 Place selected fuse in lower jumper terminal Place 2A fuse which supplies the ignition feed to the DC DC charger in top terminal Be mindful of orientation 4 Ins...

Страница 11: ...Ignition off The charger is switched off Red Flashing Fault mode Refer to the codes below for the number of short flashes followed by number of long flashes Amber Constant flashing Charging Current bo...

Страница 12: ...d auxiliary battery Red 3 1 Starter battery voltage below 9 volts 9V Red 3 2 Starter battery voltage over 36 volts 36V Red 3 3 Starter battery voltage over 33 volts 33V Red 3 4 Internal charge control...

Страница 13: ...mum charging in all conditions with no risk to the battery life or performance The Remote voltage monitoring and temperature probe also compensates for long cable runs and should be used if the second...

Страница 14: ...de Up to 3000 meters 9 843ft above sea level IP Rating IP60 in any mounting position IP65 mounted vertically with the cables exiting the charger from the bottom DIMENSIONS AND WEIGHTS Weights 21500 03...

Страница 15: ...rice of the unit under any circumstances Incidental and consequential damages are specifically excluded from coverage under this warranty This warranty does not apply to damage to units from misuse or...

Страница 16: ...MODUL SYSTEM www modul system com...