background image

 
 
 

 

 

 

Display icon

 

Function

 

Functional description

 

 

Safety Sign

 

If the “Safety Sign” is displayed normally, it means the machine is 
trouble-

free.  If  the  “Safety  Sign”  twinkling  flicker,  it  means  the 

water heater cannot be connected to the 

Ground

 firmly.

 

 

Cold Water 

Mode

 

If this function  icon appears, water heater  is not heated. Thus, the 
water will come out cold.

 

 

Morning Mode  If  this  function  icon  appears,  the  water  heater  is  in  the  “Morning 

Mode”, the default set temperature is 36°C.

 

 

Night Mode 

If  this  function  icon  appears,  the  water  heater  is  in  the  “Night 

Mode”, the default set temperature is 40°C.

 

 

Temperature 

Value 

Displaying the current hot water temperature.

 

 

Power Icon 

The  “Power”  icon  displays  the  power  output  status.  The  sign 
“Max” refers to full power.

 

 

BUTTON FUNCTION 

(EI 2D B only)

 

Display icon

 

Function

 

Functional description

 

 

Leakage 

Circuit 

Detection

 

If  the  “Test”  button  is  pressed,  this  water  heater  will  perform  the 
leakage circuit detection. Re-press (press back) the button, so the 
water heater will perform recovery.

 

 

Mode Selection

 

If  the  “Mode”  button  is  pressed,  this  water  heater  will  switch  in 
“Cold”, “Morning”, or “Night” modes.

 

 

PARAMETER SETTING MODE 

(EI 2D B only)

 

To activate this mode, do press the "Mode" button for 3 second, system will enter parameter setting 
and screen will flicker. Turn the knob to set the temperature to the desired value. Re-press the "Mode" 
button and the parameters are set successfully.

 

 

APPLIANCE OPERATION 

Switch on the power supply, the screen will be on for EI 2D B or “Earth” and “ELCB” blue indicator 
lights  will  turn  on  for  EI  2  W.  When  the  water  flow  exceeds  1.5L/min,  rotate  the  knob  clockwise  to 
switch on the power switch, the heating indicator light will be on, and the unit will start to work. 
 

LEAKAGE TEST  

[EI  2D  B]

 

When  the  water  heater  is  working  normally,  press  the  “Test”  button.  If  the  leakage  test 

circuit sho

ws no issue, the screen will off, and this water heater will not working to heat. Press “Reset” 

bottom for finishing the test, the display will be on, and the appliance (the water heater) will be back to 
working  state  as  before.    If  the  circuit  leaks,  pres

sing  “Reset”  button  would  not  cancel  the  leakage 

testing.  If  the  screen  does  not  turning  on,  it  means  the  water  heater  has  problems  and  cannot  be 
used; all the buttons are invalid and the heating stopped. If the “Safety Sign” twinkling flicker, it means 
the heater cannot be connected to the Ground firmly. Please check the Grounding before use. 
 

[EI  2  W]

 

When the water heater is working normally, press the “Test” button. If there is no founded 

problem during  leakage test circuit, the “ELCB” green indicator light  will flicker, and  the  unit  will not 
working. Press “Reset” button for finishing the test, the “ELCB” green indicator light will turn on, and 
the appliance will be back to working state set before. If the circuit leaks, pressing “Reset” button can’t 
ca

ncel leakage testing. If the “ELCB” green indicator light keeps flickering, it means the water heater 

has problems and cannot be used; all the buttons are invalid and heating stopped. If the  “Earth” blue 
indicator light turns off, it means the heater cannot be connected to the Ground firmly. Please check 
the Grounding before use. 
 

Содержание EL 2 W

Страница 1: ...User Manual Book Electric Instant Water Heater Veloce Series EL 2D B EL 2 W ...

Страница 2: ... aim to deliver stylishly designed products equipped with state of the art technology to assist you in your daily activities This is your guidebook containing everything you need to know about our product Please reach us if you need further assistance or other information via our Customer Care or our official website www MODENA com ...

Страница 3: ...E Introduction 2 Part 1 Name of Parts 4 Part 2 Important Safety Information 5 Part 3 Installation 6 Part 4 How to Use 8 Part 5 Maintenance 10 Part 6 Troubleshooting 10 Part 7 Specification 11 Part 8 Wiring Diagram 12 ...

Страница 4: ...4 EI 2D B El 2 W Part 1 Name of Parts ...

Страница 5: ...ff the Miniature Circuit Breaker MCB in advance to protect the water heater against possible damage Inspect on the built in ELCB once a month to avoid a hazard to users such as damage to property serious injury or death Do cut off the power electricity supply before any maintenance Any maintenance or adjustment towards this product by non professional is highly prohibited The damaged power cord mu...

Страница 6: ...er cord lines 4 Insert the power cord lines into the jacket for installation of the wire pressing plate 5 Tighten the wire pressing plate with the screws to primary position make sure that the power cord doesn t come loose when it is pulled at 60N force 6 Connect the end of the power cord to wiring terminals the method is as shown in the image Part 3 Installation Note The installation of every end...

Страница 7: ...all by means of a drill and insert a plastic wall anchor fischer into the hole 4 Tighten one of the screws on the top and make sure that there is the certain distance between the head of the screw and the wall see below picture 5 Install the unit on the wall and tighten two screws at the bottom connect the wires and re install the top cover with the screws PLUMBING CONNECTION 1 The water valve wit...

Страница 8: ...nding to the line in electric network WATER SUPPLY After all the process of the plumbing connection is finished open the water inlet valve of the product and supply the unit with the water to drain away the air inside until there is the stable water flow comes out from the shower head Check whether there is leakage at the joints connection or not If there is check whether the connecting parts are ...

Страница 9: ... for EI 2D B or Earth and ELCB blue indicator lights will turn on for EI 2 W When the water flow exceeds 1 5L min rotate the knob clockwise to switch on the power switch the heating indicator light will be on and the unit will start to work LEAKAGE TEST EI 2D B When the water heater is working normally press the Test button If the leakage test circuit shows no issue the screen will off and this wa...

Страница 10: ... seconds to drain away the impurities in the pipe before connecting the water source to the water heater If the unit has not been used for a long period of time check the water heater first before use Connect the water heater with power supply after the water flows out stably To avoid moisture do not spray water to the circuit breaker or the heater body directly Please cut off the power supply in ...

Страница 11: ...ign is flickering EI 2D B 1 Ground damage 2 PCB error 1 Check the grounding 2 Contact MODENA Call center for repair ELCB indicator light is twinkling flicker EI 2 W Electricity leaks Contact MODENA Call center for repair Screen display E1 EI 2D B Power indicator light is twinkling flicker EI 2 W Temperature sensor is broken Change the temperature sensor Model EI 2D B EI 2 W Rated Voltage Frequency...

Страница 12: ...12 EI 2D B EI 2 W Part 8 Wiring Diagram ...