Original instruction notice
19
NOT-MC89-EN-2020-v1
REVOLUTION COUNTER PARAMETERS
The revolution counter is set by default for a straight or right angle head (RA30) standard output shaft (STD), without Banjo
head.
When used with a BJH banjo head (see chapter 8), the number of turns and the
output speed of the actuator will be different, so you need to select “BJH01” for a
standard duty Banjo head (speed is divided by 4) or “BJH02” for a heavy duty
Banjo head (speed is divided by 3).
If you want to set a specific ratio for
speed and count, select “SP”, then
indicate of you want to multiply (“M”)
or divide (“d”) the speed and number
of turn, and set the ratio “I=” from 1.0 to 20.0.
CHANGING THE BATTERY
Use a AA 3,6V Li-SOCL2 battery
Reposition the wires correctly before tightening the 4 screws
Use a 3mm hexagonal