Start charging :
Before use, the cable must be completely unwound from the recess (1-5).
Insert the charger mains plug in the socket.
Push the battery pack (1-2) into the charging station (1-1)
Meaning of the LEDs :
After plugging the charger in the socket, all the LEDs light up for approx 1 sec. (BAT146 only). Then, the charge status
display (1-4) on the charger initially changes to the yellow LED (« self-check ») and then indicates the operating condition of
the charger :
Steady yellow LED : Charger is ready for operation
Flashing green LED : Battery pack is charging
Steady green LED : The battery pack is more than 80% charged and ready for use. In the background, the battery
pack will continue to be charged up to 100%.
Flashing red LED : General fault indicator, e.g. not in full contact, short circuit, faulty battery pack, etc.
Steady red LED : Battery temperature is outside the permitted limit values. As soon as the permitted temperature
is reached, the charger automatically switches to charging.
On the BAT146 only, the maximum remaining charging time is indicated on the LEDS (1-3)
Batteries
Technical data
BAT143
BAT144
Voltage
18 V DC
18 V DC
Capacity
5,20 Ah
6,20 Ah
Autonomy*
24 minutes
29 minutes
Charging time with
standard charger BAT145
45 minutes
53 minutes
Charging time with
quick charger BAT146
33 minutes
40 minutes
Weight
0,7 kg
0,7 kg
*Autonomy is measured with a load equal to 50% of the max torque
Instructions for use :
The battery pack is delivered partially charged. To guarantee that the battery pack provides full power, charge it completely
in the charger before using it for the first time. It can be charged at any time without reducing the battery life. Interrupting
the charging process does not damage it. The battery pack is fitted with a temperature sensor, which only permits charging
at temperatures of between 0 °C to 55 °C. This ensures a longer battery life.
The battery pack should ideally be stored in a cool (5°C to 25°C) and dry location (air humidity < 80 %). Significantly
shorter operating times after each charge indicate that the battery pack is worn and should be replaced with a new one.
Observe instructions regarding disposal.
Capacity display
When pressing the button,[1-1] the charge indicator [1-2] shows the charge of the battery pack during approx. 2 s :
3 LED : Battery pack is charged > 70%
2 LED : Battery pack is charged between 40% and 70%
1 LED : Battery pack is charged between 15% and 40%
1 LED flashing : Battery pack is charged < 15%
Charge the battery pack before any further use. Do not continue until
complete discharge.
After the portable actuator has switched off automatically, do not press the on/off button, this could damage the battery pack.
BAT14
6
BAT146