WALL MounTIng
WITH BR ACkE T
Allow the Heat Sensor to reach room temperature before use. The power to the
cooker must be switched off (at the consumer unit). See the table below for
the mounting location and follow instructions 1–5.
Starting the Heat Sensor
Insert the battery and place the
Heat Sensor on the installation
plate.
Press the button shortly.
(LED flashes green).
Set the sensitivity level
Set the Heat Sensor's sensitivity level according to the mounting height
(as described in the table) by evenly pressing the Sensor's button.
The factory setting for the sensitivity level is 45–60 cm above the cooker.
(Please refer to the table underneath together with the information on
page 18, alternatively watch the film on sensitivity configuration).
DISTANCE FROM COOKER TO HEAT SENSOR
SENSITIVITy LEVEL CONFIGURATION
Sensitivity
Acknowledgement “beep(s)”
70–80 cm
*
3 presses
65–69 cm
*
4 presses
* 80cm recommended. For wall mounting with a distance less than 80cm between
the Heat Sensor and the cooker, the installation may not in all cases meet all EN
standard requirements.
Please note: the sensitivity level of the Sensor is confirmed by the
appropriate sound pattern sequence only and not the LED flashes.
4