3.4 CONNECT AN EXTERNAL POWER SUPPLY (OPTIONALLY)
Although the Mobeye CML2285 is designed to run on batteries, it is possible to use
an external power supply. In this mode the module is always connected with the
GSM network and therefore always in program mode. When the power fails, the
batteries take over and a power failure alarm message is sent. The module
continues operating albeit in the low power mode. This means the GSM module
switches off and only establishes network connection when it needs to send an
alarm notification, test message or low battery alert.
Connect the external power adapter (or any
other regulated 12VDC power supply) to the
power input of the connector (press on the
green pins to connect the wires):
- V+ (black lead w
ith white stripe) to “+”
- Ground (black l
ead) to “-“
3.5 CONNECT A SENSOR TO THE INPUTS (OPTIONALLY)
It is possible to connect external (NO/NC) sensors to the inputs. A triggered input will
lead to alarm notifications.
Insert the 2 wires of the external sensor through the swivel in the enclosure and
insert them in the two connectors of input 2 (press on the green pins for connecting
the wires). It does not matter which wire is connected to which connector.
As default the inputs are programmed as
Normally Open (NO) contacts. This means the
inputs are triggered if the input is closed for at
least 1 second. In case the contact is Normally
Closed (NC), please refer to paragraph 0. If you
require the sensor to be activated for a shorter or