5.  POSSIBLE SETTINGS 

The Mobeye Panic Button has many setting options that influence the behaviour of 
the module. If connected on the Mobeye Internet Portal, the settings are prepared in 
the  portal  (see  chapter  4).  If  your  own  SIM  card  is  used,  programming  is  done  via 
SMS commands (see chapter 6). 

5.1  ALARM PHONE NUMBERS 

In  the  event  of  an  alarm,  the  Mobeye  Panic  Button  can  call  5  telephone  numbers 
(TEL1…  TEL5).  It  is  possible  to  confirm  a  call  by  picking  up  the  telephone  and 
pressing any key. The following numbers will not be called. 
When  using  your  own  SIM  card,  it  is  mandatory  to  set  at  least  one  number  (on 
TEL1). The TEL1 ... TEL5 are then used for telephone calls and / or text messages 
from the unit. 
This  is  not  mandatory  when  using  the  Mobeye  Internet  Portal.  If  no  telephone 
numbers  have  been  entered,  the  notifications  will  only  be  sent  to  the  portal  and 
forwarded by SMS and / or e-mail from there.  
Note: the (unlimited number of) contacts who receive SMS / e-mail may be different 
from the numbers programmed on TEL1 ... TEL5. 

5.2  CALL ON/OFF 

Even if the alarm telephone numbers are set in the options, the calling process can 
be  suppressed.  By  turning  off  the  CALL,  the  unit  will  only  send  the  notification  via 
textual messages. The default value is set to "ON". 

5.3  SMS ON/OFF 

This  setting  is  only  relevant  when  using  your  own  SIM  card:  the  Mobeye  Panic 
Button  alerts  after  an  alarm  on  the  inputs  with  a  call  and  an  SMS.  It  is  possible  to 
turn off the SMS (OFF). As a factory setting, the SMS is set to "ON". 

Содержание CM2500

Страница 1: ...USER MANUAL Mobeye Panic Button CM2500 SW version 5 n...

Страница 2: ......

Страница 3: ...device from moisture heat and water splashing Not intended for external use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from...

Страница 4: ...device in the portal 13 4 5 Configuration and synchronisation 14 4 6 Basics of the Mobeye Internet Portal 14 4 7 Confirmation of the alarm message 16 4 8 System reset 16 5 Possible settings 17 5 1 Ala...

Страница 5: ...4 7 4 SMS reports when using own SIM card 25 7 5 Technical messages 26 8 Status feedback 27...

Страница 6: ...5...

Страница 7: ...net Portal In this management environment the device is given additional functions such as online programming status and history display more options for forwarding messages and it will monitor test m...

Страница 8: ...is used and a power failure occurs the Mobeye Panic Button sends a power failure message to Mobeye Internet Portal to be forwarded to the alarm contacts When the power is restored the Mobeye Panic But...

Страница 9: ...er In case external emergency buttons are connected to the external inputs and these are activated the Mobeye Panic Button sends an alarm SMS text message and calls the phone numbers programmed in by...

Страница 10: ...e Mobeye Internet Portal e Program the options and synchronise 6 Programming when using your own SIM card a Enter the program mode b Program the settings Steps 1 to 4 are described in sections 3 1 up...

Страница 11: ...ettings will not be deleted since they are stored in the device memory 3 3 CONNECT AN EXTERNAL POWER SUPPLY OPTIONALLY Although the Mobeye Panic Button is designed to run on batteries it is possible t...

Страница 12: ...insert them in the two connectors of input 1 press on the green pins for connecting the wires It does not matter which wire is connected to which connector A second button can be connected to input 2...

Страница 13: ...rnet Portal choose activate SIM card on the Add Device screen Fill in the SIM card number This is the number written on the plastic SIM card below the barcode You can take the entire number or only th...

Страница 14: ...g 3 minutes the GSM module remains active ready to be activated in the portal In a battery operated unit a time out occurs after 3 minutes and the GSM module switches off in order to save the batterie...

Страница 15: ...e network 4 6 BASICS OF THE MOBEYE INTERNET PORTAL Dashboard With multiple devices the dashboard shows all devices with the alarm messages in the last 24 hours missed test messages and low battery sta...

Страница 16: ...ges you link the contact persons who receive alarm and service messages via text message and or e mail Service messages can be warnings about missed test messages and low battery voltage To add a cont...

Страница 17: ...elete the Mobeye Panic Button from the Mobeye Internet Portal Go to Device Settings and click on the delete icon in the Device block Then confirm your choice 2 To reset the Mobeye Panic Button to its...

Страница 18: ...r telephone calls and or text messages from the unit This is not mandatory when using the Mobeye Internet Portal If no telephone numbers have been entered the notifications will only be sent to the po...

Страница 19: ...be triggered as soon as the terminals of the input are closed If the input is set to NC the alarm is triggered when the connection between the input terminals is broken The default input type is set t...

Страница 20: ...The time can be set between 0 and 999 minutes As default the delay time is set to 0 5 10 TEST MESSAGE When using the Mobeye Internet Portal The Mobeye Panic Button can send regular test messages keep...

Страница 21: ...test SMS messages keep alive to the first phone number TEL1 to ensure the proper functioning of the unit The test message function is only active if the unit is armed The timing of the test message i...

Страница 22: ...ally takes 10 30 seconds As soon as the network has been established and the program mode has been reached the LED flashes 1 sec on 1 sec off or stays on continuously in case the unit has been configu...

Страница 23: ...d an SMS text message with the security code and the command 3 The green LED blinks 3 times to indicate the successful configuration In case of an incorrect command the red LED flashes 5 times SMS mes...

Страница 24: ...ON OFF ON SMS on off SMS ON OFF ON Priority of message PRIORITY CALL MESSAGE MESSAGE Input type input 1 TYPEIN1 NO NC NO Input type input 2 TYPEIN2 NO NC NO Delay on on off button DELAYBUTTON 0 999 s...

Страница 25: ...e you will hear beeps It is possible to acknowledge the phone call by answering the phone and pressing any key The other alarm numbers will not be called afterwards This works for most telephones By s...

Страница 26: ...power and batteries SMS command status request STATUS example 1111 STATUS LIST OF SETTINGS The settings can be requested by sending following SMS text message SMS command list basic settings SET SMS c...

Страница 27: ...ernal power is restored or the adapter is plugged in a socket batteries do not need to be replaced delayed message If delayed message is added to the SMS text messages the message couldn t be sent ear...

Страница 28: ...he network connection is established 2 flashes red every 3 seconds No GSM connection Try the SIM card in any mobile telephone replace SIM card using other telecom provider try the module at another lo...

Страница 29: ...x ca 500 mA Power consumption 12V ca 50 mA stand by max ca 500 mA Dimensions 80 x 60 x 30 mm Ambient temperature 10 C until 50 C This manual is published by Mobeye All rights the translation included...

Страница 30: ...29...

Страница 31: ...30...

Страница 32: ......

Отзывы: