Enter the four octets of the subnet mask step by step.
Switch to the next octet by pushing the
PB1S
button.
The octets are marked by the letters
A
,
b
,
C
and
d
.
By pushing the
PB1L
button, the entered values are stored and the clock returns to the
menu item
P10.
Push together
PB1L
and
PB2L
to return to
P10
without storage of the data
8.2.4 Manual setting of the default gateway IPv4 address
Choose the item
P11
in the main menu and push the
PB1L
button to enter the
submenu for setting the default gateway IP address. The item to be set is blinking.
By pushing
PB2S,
the adjusted digit value is increased in steps of 1; by pushing the
PB2L
button, the value will be continuously increased.
In der Anzeige erscheint:
Enter the four octets of the gateway IP address step
by step. Switch to the next digit or octet respectively by
pushing the
PB1S
button. The octets are marked by
the letters
A
,
b
,
C
and
d
.
By pushing the
PB1L
button, the entered values are stored and the clock returns to the
menu item
P11.
Push together
PB1L
and
PB2L
to return to
P11
without storage of the data
8.2.5 Submenu for setting the IPv4 multicast group address
Choose the menu item
P12
and then enter the submenu by pushing the
PB1L
pushbutton for setting the multicast group address. The item to be set is blinking.
By pushing the
PB2S
button, the adjusted digit value is increased in steps of 1; by
pushing the
PB2L
button, a continuous increase of the value takes place.
The display shows the following:
Enter the four octets of the IP address step by step.
Switch to the next digit or octet respectively by pushing
the
PB1S
button. Octets are marked by the letters
A
,
b
,
C
and
d
.
By pushing the
PB1L
button, the entered values are stored and the clock returns to the
menu item
P12.
Push together
PB1L
and
PB2L
to return to
P12
without storage of the data
8.2.6 Submenu for setting of the NTP unicast synchronization
Choose the menu item
P13
then enter the submenu by pushing the
PB1L
pushbutton
for setting the parameters of the NTP unicast synchronization. The item to be set is
blinking.
By pushing the
PB2S
button, the adjusted digit value is increased in steps of 1; by
pushing the
PB2L
button, the value will be continuously increased.
The display shows the following:
Set the four octets of the NTP server’s IP address step
by step. Switch to the next digit or octet respectively by
pushing the
PB1S
button. Octets are marked by letters
A
,
b
,
C
and
d
.
After the last octet setting, set the constant x which determines the interval of
synchronization in seconds.