![MMF VM24 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/mmf/vm24/vm24_instruction-manual_1813940022.webp)
A: New condition
B: Good condition for unrestricted continuous operation
C: Poor condition - allows restricted continued operation only
D: Critical condition - Danger of damage to the machine.
v
ef
f
1
0
–
1
00
0
H
z
45 mm/s
28 mm/s
18 mm/s
14.7 mm/s
Zone
C/D
4,5 – 14,7
mm/s
11.2 mm/s
9.3 mm/s
Zone
B/C
1,8 – 9,3
mm/s
7.1 mm/s
4.5 mm/s
Zone
A/B
0,71 – 4,5
mm/s
2.8 mm/s
1.8 mm/s
1.12 mm/s
0.71 mm/s
0.45 mm/s
0.28 mm/s
D
Risk of machine damage
C
Restricted continued operation
B
Unrestricted operation possible
A
Newly commissioned machine
Table 1:Typical zone limit values for vibration severity according to ISO 10816-1
In the standard it is pointed out that small machines, for example electric motors
with a power rating of up to 15 kW, tend to lie around the lower zone limits,
whereas large machines, for example motors with flexible foundations, lie around
the upper zone limits..
20
Содержание VM24
Страница 4: ...2 Figure 1 VM24 with Sensor...