With the aid of a cross-head screwdriver, remove the cover to access the mains terminal block (see Fig 2)
• Connect the luminaire to the mains supply ensuring that correct polarity is observed: L - Live (brown), E -
Earth (green/yellow), N - Neutral (blue) (see Fig. 3)
Fig. 1
Fig. 2
INSTRUCTIONS
–
RW5xx
These instructions should be read carefully and retained after installation by the end user for future reference and
maintenance.
These instructions should be used to aid installation of the following products:
RW5WW / RW5CW
SAFETY
•
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
•
Please isolate mains prior to installation or maintenance
•
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating
of the circuit cable, fuse or circuit breaker
•
Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for
installation
•
If used under insulation, the insulation should be laid unbroken over the luminaire (not packed
around it). Only mineral wool style insulation may be used
•
This product is Class I and must be earthed
•
This product series is IP65 rated
INSTALLATION
Note
- If this luminaire is being used in conjunction with an external PIR or sensor, please confirm with
the manufacturer of the sensors that they are compatible with LED luminaires
•
Provide power to the required point of installation
•
Cut a suitable hole in the mounting surface as per the cut-out details (see Fig. 1) ensuring not to
infringe with any joists, gas / water pipes or electrical cables
Fig. 1
•
With the aid of a cross-head screwdriver, remove the cover to access the mains terminal block (see
Fig 2)
Fig. 2
•
Connect the luminaire to the mains supply ensuring that correct polarity is observed: L - Live
(brown), E - Earth (green/yellow), N - Neutral (blue) (see Fig. 3)
Fig. 3
•
Secure the mains cable under the cable clamp and refit the terminal cover
•
To remove the bezel, turn anti-clockwise
•
To refit the bezel, turn clockwise
•
Lift both spring clips on the sides of the fitting and push into the ceiling
•
Switch on and check for correct operation
WARNING
This luminaire must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed
GENERAL
The LED lamps fitted in this product are non-replaceable. The product should be recycled in the correct manner
when it reaches the end of its life. Check local authorities for where facilities exist
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the
product
This product is dimmable with most trailing edge dimmers
WARRANTY
L
L
E
E
N
N
Содержание RW5WW