Fig. 1
• The spike of the luminaire is required to be pushed fully into the ground
• If installing outdoors, please ensure an RCD or RCBO is used
• The power source connections should be local and accessible via a suitable IP rated enclosure
• The fittings must be wired IN SERIES to the secondary side of the constant current driver (see Fig.
2). The minimum and maximum load of the driver must be observed
• We recommend that a maximum cable run of 10m of 0.75mm² CSA cable be used in the series
circuit
• The junction box IP68JBS can be used for the connection of up to three fittings at a time
• Connect the + (brown) and – (blue) ends of the series loop into the secondary terminals of the
constant current driver
• Connect the constant current driver to the Live (brown) and Neutral (blue) of the mains supply
• Switch on and check for correct operation
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation
resistance testing. Irreparable damage will occur if this instruction is not followed
Care must be taken if these fittings are required to be installed in a special location as defined by
BS7671, this is because the maximum secondary voltage of the driver may exceed the maximum
voltage requirements of the location
3
•
The junction box IP68JBS can be used for the connection of up to three fittings at a time
Fig. 2
•
Connect the + (brown) and – (blue) ends of the series loop into the secondary terminals of the
constant current driver
•
Connect the constant current driver to the Live (brown) and Neutral (blue) of the mains supply
•
Switch on and check for correct operation
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed
Care must be taken if these fittings are required to be installed in a special location as defined by BS7671, this is
because the maximum secondary voltage of the driver may exceed the maximum voltage requirements of the
location
GENERAL
The LED lamps fitted in this product are non-replaceable. The unit should be recycled in the correct manner
when it reaches the end of its life. Check local authorities for where facilities exist
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the
product
Do not use any source of high pressure washers to maintain or clean this luminaire
This product is not suitable for installation in or near a coastal or marine environment
A light film of acid free oil is recommended after installation and maintained periodically (2-3 times a year) to aid
corrosion prevention
This product is non-dimmable
WARRANTY
This product has a warranty of 1 year from date of purchase. Failure to install this product in accordance with the
current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch codes will
invalidate the warranty. If this product should fail within its warranty period it should be returned to the place of
purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation
costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve the
right to alter product specification without prior notice.
DCDEC18_V2
Fig. 2