![MKS T3B Series Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/mks/t3b-series/t3b-series_supplement-manual_1813372057.webp)
51
R8
Get Valve Slip (C0=no, C1=slip)
R87
Get Local preset softstart pressure
R88
Get Local preset softstart position
RAI
Get Valve Air Interlock Status
RB
Get Status of Backfill Relay - Open/Close
RBD
Get Backfill Delay
RBE
Get Backfill Valve Enable/Disable
RBL
Get Backfill Control Limit
RCD
Get Pump Speed Data Table Data
RCH Get
Checksum
RCL
Get channel lock
RCP
Get Pump Speed Table Pedestal
RCT
Get Pump Speed Data Table Number
RCV
Get Pump Speed Data Value
RD
Get Auto Crossover Delay
RDO Get
Device
Option
REN
Get Encoder Valve Position (% Open)
RGC
Get Gain Compensation Factor -
RHC
Get High Channel Crossover
RHR
Get High sensor Range
RIE
Get Interlock Enabled Status
RIN
Get Valve Interlock Status
RJT
Get Valve Type - Duplicate or R23
RLC
Get Low Channel Crossover
RLE
Get Estimated Learn Flow
RLF
Get Learned Flow
RLP
Get Analog Input filter samples
RLR
Get Low sensor Range
RLS
Get Process Limit Source
RMD
Get Backfill Threshold Pressure
ROC
Get Analog Out Calibration status
ROI
Get Analog Output Input (as % of 10VDC )
ROM
Get Operating Mode
ROS
Get Analog Output Source
RPC
Get Phase Compensation Factor
RPO
Get Platform Option (B or P)
RRS
Get Relay A/B Status
RSE
Get Slow Pump Enable
RSN
Get Serial Number of the Unit
RSR
Get Slow Pump Rate
RSS
Get Valve Safe State Open/Close/Hold
RTC
Report valve temperature in Celsius
RTF
Report valve temperature in Farenheit
RUE
Get Speed Up Enable Setting
RUF
Get Speed Up Filter Setting
RUT
Get Speed Up Time Setting
RVE
Get Volume Estimate Status Enable 1 is On,
0 is Off
RVO
Get Chamber Volume Setting
RVS
Get Span Valve Steps
RZZ
Get Devicenet service state
S1
Setpoint Value A
S2
Setpoint Value B
S3
Setpoint Value C
S4
Setpoint Value D
S5
Setpoint Value E
S6
Analog Setpoint Value
S7
Set Local preset setpoint pressure
S8
Set Local preset setpoint position
S
Set Slow Pump recipe and value
SCD
Set Pump Speed Data
SCP
Set Pump Speed Pedestal
SCT
Switch Pump Speed Table
SE
Set Slow Pump Enable
SHR
Set High sensor Range
SLF
Set Learn Flow
SLR
Set Low sensor Range
SR
Set Slow Pump Rate
SS0
Set Valve Safe State - Open Valve
SS1
Set Valve Safe State - Close Valve
SS2
Set Valve Safe State - Hold Valve
SS4
Set Valve Safe State - Cycle Valve
STA
Set Tau
STD
Set Nonlinear Flow Observer Tau
STE
Set Nonlinear Trajectory Shape
STF
Set Nonlinear Trajectory Tau
SUE
Set Speedup Enable 1 is On, 0 is Off
SUF
Set Speedup Filter
SUT
Set Speedup Time
SVE
Set Volume Estimate Enable 1 is On, 0 is Off
SVN
Set Valve Normal Mode
SVO
Set Chamber Volume