Chapter Two: RS-232 Message Summary
The RS-232 messages required for operation of the device are listed below alphabetically—by command.
\
A0
Analog Setpoint Range (5v)
A1
Analog Setpoint Range (10v)
BD Backfill
Delay
BE0
Backfill Valve Disable
BE1 Backfill
Valve
Enable
BL
Backfill Control Limit
C
Close Valve
CAL
Set Operating Mode = CAL
CB
Close Back Fill Relay
D0
Activate Analog Setpoint
D1
Activate Setpoint A
D2
Activate Setpoint B
D3
Activate Setpoint C
D4
Activate Setpoint D
D5
Activate Setpoint E
D6
Activate Analog Setpoint
D7
Restore local preset pressure
D8
Restore local preset position
EH
Set Sensor Range High
EL
Set Sensor Range Low
F
Pressure Units (Torr, mbar, etc.)
FAC
Set Operating Mode = FACTORY
G
Sensor Signal Input Range
GC
Set Gain Compensation Factor
H Hold
Valve
HB
Dump History Buffer To The Serial Port
I1
Set SoftStart Setpoint A % Value
I2
Set SoftStart Setpoint B % Value
I3
Set SoftStart Setpoint C % Value
I4
Set SoftStart Setpoint D % Value
I5
Set SoftStart Setpoint E % Value
I6
Set SoftStart Analog Setpoint % Value
I7
Set SoftStart Open Valve % Value
I8
Set Softstart Close Valve % Value
IE
Interlock Enabled (0 or 1)
IL7
Set Local preset softstart pressure
IL8
Set Local preset softstart position
IX
Reset (Power Cycle)
J
Learn Valve T3X
JT
Set Valve Type
L
Learn the System (Pump Speed)
LA
Select Auto-Dual Channel Operations
LD
Auto Crossover Delay
LH
Select High Channel Operations
LHC
High Channel Crossover
LL
Select Low Channel Operations
LLC Low
Channel
Crossover
LPF
Set the Low-Pass Filter time constant (ms) for
reporting pressure (default:100ms)
M1
Gain Setpoint Value A
M2
Gain Setpoint Value B
M3
Gain Setpoint Value C
M4
Gain Setpoint Value D
M5
Gain Setpoint Value E
M6
Gain Setpoint Value Analog Setpoint
M7
Local preset pressure gain
MD
Backfill Threshold Pressure
N
Clear any overrides (e.g. open, close, hold)
N0
Set Valve Action Normal
N1
Set Valve Action Reverse
O Open
Valve
OB Open
Backfill
Relay
OF1
Calibrate Analog Pressure Out Full Scale
OF2
Calibrate Analog Position Out Full Scale
OI1
Analog Out Pressure Input
OI2
Analog Out Position Input