10
The driving current must be converted by measuring the driving voltage. To measure the driving voltage Vref, refer
to the following figure.
The Vref can be adjusted according to the running condition of the motor, and the upper knob can be adjusted by
adjusting (clockwise to increase, counterclockwise to decrease).
Note: Before the adjustment knob, it must be done in the case of power failure. After the adjustment is completed,
the power-on measurement is taken to prevent the drive from burning out.
Formula
I=Vref/0.8
I=Vref*2
I=Vref*2
I=Vref/1.414
I=Vref*1.9/2.5