Set Point Specifications
Appendix A: Product Specifications
38
Set Point Specifications
Set Point Relay Configuration
2 separate circuits, on the PDR-C-2C they can be
connected to either pressure channel with rear mounted
toggle switches.
Contact Configuration
Single Pole Form C (SPDT) brought out to the rear panel.
One for each set point.
Contact Rating
2A @ 28 VDC, 1A @ 120 VAC resistive.
Set Point Hysteresis
0.5% of full scale
Set Point Adjustment Range
100% of full scale (coarse and fine)
Relay Control
Digital Low on relay latch line holds the relay off once it
has been de-energized.
BCD Outputs (optional)
Output parallel line BCD (1 TTL load each TTL and
CMOS compatible).
Due to continuing research and development activities, these product specifications are subject to change without notice.