Description of the unit
30
Operating instructions
3.6.2 Temperature standard setting
The adjustment range for the cooking zone temperature depends on
the cooking mode.
Cooking mode
Standard value
(°C)
Adjustment
range (°C)
Alteration
increments (°C)
Steaming
100
30 - 130
1
Combisteaming
150
30 - 250
1
Hot air
180
30 - 300
1
Regeneration
50
30 - 150
1
3.6.3 Cooking zone humidity standard setting
The setting range for the cooking zone humidity depends on the type
of cooking.
Type of
cooking
Standard value
(%)
Setting range
(%)
Change
increments (%)
Steaming
100
90 - 110
90 - 100 - 110
Combisteaming
90
20 - 100
20 - 40 - 70 - 90 -
100
Hot air
100
0 - 100
0 - 25 - 50 - 75 -
100
Regeneration
100
0 - 100
0 - 25 - 50 - 75 -
100
10013865-0ABBE-B