VOLTAGE:
120v
CYCLE:
60hz
PHASE:
1-phase
SETUP, ADJUSTMENT AND OPERATION
MK-101 PRO SERIES Setup for Operation:
1. Before powering or starting, check for damage that could prevent this equipment from proper
RSHUDWLRQRUSHUIRUPLQJLW·VLQWHQGHGIXQFWLRQ&KHFNIRUELQGLQJDQGSURSHUDOLJQPHQWRI
moving parts. Check for damaged, broken, or missing parts.
2. Verify the On/Off switch is in the OFF position.
3. Before connecting the MK-101 to a power supply, be sure the voltage, cycle and phase of the
job site power source meet these requirements;
4. I f using an extension power cord, make sure, the length and wire gauge correspond to the require-
ments listed in on page 9. An extension power cord that is too small in wire gauge
(diameter), or too long in length, will cause the motor to overheat and could cause premature failure.
5. Use an approved Ground Fault Circuit Interrupter (GFCI)
6. Do not cover the motor vents as this could lead to motor overheating.
NOTE: In order to avoid breaker tripping, a 20-amp circuit breaker should be used.
Portable Generator:
If using a portable generator, ensure the generator meets the following minimum requirements:
5 KW 120/240 volts
41.7/20.8 amps Single Phase
Ground Fault Circuit Interrupter
Set Cutting Depth:
When loosening the Cutting Head Adjusting Knob, the Cutting Head will pivot down unless held.
(A)
Ensure the ON/OFF Switch
is in the OFF position.
(B)
Plug MK-101 into the GFCI.
(C)
Plug the GFCI into the
power source*.
(A)
Loosen Cutting Head
Adjusting Knob.
(B)
Set cutting depth approximately
1/4 to 1/2 inch below the
surface of the Movable
Cutting Table.
(C)
Tighten the Adjusting Knob.
*A GFCI wall socket is the preferred protective device.
CAUTION
CAUTION