Display Settings
There are 3 operational values on your CobraMig 300 User Interface.
Heat
: Is a reference value from 0-10, which controls the voltage output,
(Actual voltage will display during welding)
Wire Speed
: Wire speed displayed is from 0-800 (Displays in inches/ minute)
Memory
: 1-8 User memories available
Press
‘SELECT’ button
either on the gun or front display to switch between
operational settings.
The
LED light
will illuminate which setting is active.
Use
adjustment knob
or the
( + )
or
( - )
Button on the gun
to adjust the
value up or down.
Section B
On/Off
switch
Adjustment
Knob
Select
Button
Wire Speed/
AMPS
Display
Memory
Display
Heat/ Volts
Display
Note: Once arc is established during welding, actual welding Voltage and
Amps will be live and displayed on the user interface. After welding, actual
Volts and Amps will remain displayed for three seconds before resetting back
to Reference Voltage and Wire Speed. See example above.
~ All parameters are automatically saved per user memory~
(See advanced parameters S 04 for more details)
Содержание COBRAMIG 300
Страница 26: ...Cobra X Owner s Manual Page 20 Assembly Power Supply CM300 187 201...
Страница 27: ...Cobra X Owner s Manual Page 21 Assembly Power Supply CM300 187 201 cont...
Страница 28: ...Cobra X Owner s Manual Page 22 Assembly Wire Feeder CM300 187 101...
Страница 29: ...Cobra X Owner s Manual Page 23 Assembly Wire Feeder CM300 187 101 cont...
Страница 31: ...Cobra X Owner s Manual Page 25 X Series Gun Electrical...
Страница 32: ...Cobra X Owner s Manual Page 26...
Страница 33: ...Cobra X Owner s Manual Page 27...
Страница 34: ...16882 Armstrong Ave Irvine CA 92606 Tel 949 863 1234 Fax 949 474 1428 www mkproducts com August 1 2010...
Страница 35: ...THIS PAGE INTENTIONALLY BLANK...
Страница 36: ...www mkproducts com 16882 Armstrong Ave Irvine California 92606 TEL 949 863 1234 FAX 949 474 1428...