BX-3
Revision 11/00, Effective Date November 1, 2000
Page 20
MAINTENANCE AND TROUBLESHOOTING
4. Diamond Blade Change-out:
Disconnect the tool before servicing and when changing accessories, such as blades, bits,
cutters, and the like.
NOTE: When installing the Retaining Screw, do not “cross-thread" and DO NOT over tighten the screw.
(A)
Setup BX-3 for Operation
(B)
Remove Retaining Screw
and Outer Flange
(C)
Remove Blade from
Motor Shaft
(E)
Install Outer Flange and
Retaining Screw – Tighten
(D)
Install Blade Under Blade Guard
and Onto Motor Shaft
Rotate Blade
Wrench Clockwise
Retaining Screw
Hold Shaft
Wrench
Stationary
Seat Blade on
Inner Flange
Rotation Direction
Hold Shaft
Wrench
Stationary
Rotate Blade
Wrench
Counter-clockwise
Set up for Operation
(See Setup, Adjustment
and Operation)
Remove Blade