BX-3
Revision 11/00, Effective Date November 1, 2000
Page 17
SETUP, ADJUSTMENT and OPERATION
6. Cleanup:
Always wear eye protection when using compressed air.
(B)
Unplug GFCI from BX-3
(C)
Remove Motor Filter Cap
(A)
Unplug GFCI from Power Source
(E)
Clean Filter by Tapping on Hard
Surface or using Compressed Air
(D)
Remove Filter from Filter Cap
(H)
Clean the Movable Cutting Table
Roller Wheels and Guide Rails
(G)
Install Motor Filter
Cap onto Motor
(F)
Reinstall Filter into Filter Cap
(I)
Clean Remainder of BX-3
Tap on Hard
Surface to
Dislodge Dirt
Power
Source
GFCI
Pull Foam Filter
Out of Filter Cap
Align Filter Cap
Retaining Clips
to Spacer Pins
Push Filter Cap
onto Spacer
Pins to seat
Clean Guide Rails
Clean BX-3
Using Clean Cloth
Pull Straight Back
To Remove Cap
Install Foam Filter
into Filter Cap
Clean Roller
Wheels