Operating Instructions MG3 Digital
Integration in Automated Installations
76609409EN-BA-MG3D-V1_6.docx 75/82
2010-08-02
6.10
Flow Chart 2 channel part detection with current
Dia9-MG3
MG3D
global ready
Zero
current 2
Zero
current 1
good/poor
Ch1 and Ch2
Current
output 2
Current
output 1
Part
available 2
Part
available 1
Current
signal 1
of coil
Part
evaluation 2
Part
evaluation 1
Start part
detection 2
Start part
detection 1
Evaluation of IO complete
0 = no part available
1 = part available
X38.50 Input
X38.49 Input
X38.48 Input
X38.47 Input
IK1 input current coil
X38.25 Output
X38.26 Output
X54.2 output
X54.8 output
X54 outputs
X54.17 output
X54.21 output
IK2 input current coil
X54.1 output
from here new sequence
start measuring part detection ch2 (X38.49)
part evaluation ch1 (X38.48)
part evaluation ch2 (X38.47)
start measuring part detection ch1 (X38.50)
0 = no part available
1 = part available
Current
signal 2
of coil