CHAPTER 3: OPERATING CONTROLS AND SCREENS
875DP/500DP/500HV DUAL PULSE
RESISTANCE WELDING
POWER SUPPLIES
3-4
990-290
A.
Schedule number (0 - 15)
B.
Polarity of output welding pulses
C.
Energy of Weld Pulse 1
D.
Energy of Weld Pulse 2 (dual pulse)
E.
Type of weld head and foot switch
F.
Graphic display of Weld Pulse 1 energy
G.
Weld counter step count for next
schedule
H.
Pulse width of Weld Pulses 1 and 2
I.
Next schedule number (1-15) in chain
J.
Present state of power supply
K.
Weld Sentry program lines – Program
(A-E), last weld results, measurement
unit, upper/lower limits, Sentry status
L.
Weld function: basic, repeat or roll-spot
M.
Weld counter step count for next
schedule
N.
Pulse width of Weld Pulses 1 and 2
O.
Switching status of output relays
P.
Run state with NO WELD switch ON
Q.
Typical multi-page help screen
SCHEDULE
001
PULSE 1
10.0 %
PULSE 2
35.0 %
BASIC WELD
POLARITY:(+)
WIDTH:SHORT
AIR HEAD 2-L
WELD#:00001
NEXT :001
AMP-SECONDS
LOWER UPPER SENTRY:001A
299.1
• •
270.0
• •
310.0
• •
READY
Select Schedule
RUN
RUN Screen with Weld Sentry
K
SCHEDULE
001
PULSE 1
10.0 %
PULSE 2
35.0 %
BASIC WELD
POLARITY:(+)
WIDTH:SHORT
AIR HEAD 2-L
COUNT: 00001
NEXT :001
RELAY 1 :
RUN STATE
RELAY 2 :
ON
OFF
Select Schedule
NO WELD
NO WELD Screen
P
PROGRAM Screen
L
SCHEDULE :001
NEXT SCH :011
MODE
:BASIC
STEP CNT :0001
POLARITY :[ + ]
WIDTH
:SHORT
PULSE 1
PULSE 2
ENERGY
:010.0%
035.0%
RELAY 1 :RUN STATE
RELAY 2 :ON
OFF
Select, NUMBER Change
PROGRAM
M
N
O
HELP Screen
Q
[HELP] [PULSE 2]
PAGE 2/3
DUAL PULSE IS USED TO WELD PLATED MATER-
IALS. PULSE 1 SHOULD MAKE A LIGHT TACK
WELD AND PULSE 2 SHOULD WELD TO BASE
METAL. PULSE 2 IS USUALLY SET TO 3
TIMES THE ENERGY OF PULSE 1.
TO WELD SMALL WIRES TO SUBSTRATE: USE
Last
HELP to Return
Next
MAIN MENU
OPTIONS
WELD SENTRY
WELD COUNTERS
CALIBRATE 250DP
COPY A SCHEDULE
RESET TO DEFAULTS
SYSTEM SECURITY
INSTALLATION
SYSTEM HELP
Last
HELP to Return
Next
MAIN MENU Screen
SCHEDULE
001
PULSE 1
10.0 %
PULSE 2
35.0 %
BASIC WELD
POLARITY:(+)
WIDTH:SHORT
AIR HEAD 2-L
WELD#:00001
NEXT :011
Select Schedule
RUN
RUN Screen
A
B
C
D
E
F
G
H
I
J