Installation: remote mounting
For 120L units and in some cases where limited space or pre-existing
pipework obstruct the normal mounting position of the exchanger
assembly, it may be required to mount the assembly a small distance
away from the cylinder. In this situation, please follow the guidance
below:
•
Ensure that a minimum of 22mm pipework is used to connect the
exchanger assembly to the heat exchanger ports on the cylinder.
Do not exceed more than 2m of additional pipework and reduce
the number of bends in the pipework to a minimum.
•
Ensure the exchanger assembly is adequately supported with
a minimum of 3 wall mounted pipe clips within 300mm of the
assembly.
•
Ensure all pipework running to and from the assembly is fully
lagged.
•
Ensure the orientation and plumbing of the installed pipework
matches that of the hydraulic schematic (