17
-
'18 • SRK-T-250
Hole on wall for right rear piping
Hole on wall for left rear piping
Gas piping
Outlet for piping
(
on both side
)
Drain hose
F
E
C
D
Symbol
A
(
φ
65
)
VP16
Content
(
φ
65
)
SRK20, 25, 35
φ
9.52
(
3
/
8"
)(
Flare
)
Wireless remote control
SRK50
φ
12.7
(
1
/
2"
)(
Flare
)
Wired remote control
(
Option
)
φ
6.35
(
1
/
4"
)(
Flare
)
Liquid piping
B
Space for installation and service when viewing from the front
Unit:mm
Notes
(
1
)
The model name label is attached
on the right side of the unit.
(
2
)
To connect the wired remote control,
the interface kit
(
SC-BIKN2-E
)
is required.
□120
19
60
24
167
45
45
870
290
Outlet for downward piping
(
Refer to the top view
)
230
3
60
13
530
450
185
190
43
170
585
13
(
Service space
)
Unit
(
Service space
)
(
Service space
)
Installation board
142.5
142.5
100
50
9
47
268
47
80
100
Terminal block
60
35
35
60
□120
19
210
55
55
537
528
SRK 50
:475
(
Service space
)
170
210
435
435
SRK 20,25,35
:469
45
F
D
E
A
B
C
F
F
φ
9.52
(
3
/
8"
)
(
Flare
)
Content
C
Pipe
/
cable draw-out hole
D
E
Anchor bolt hole
Drain discharge hole
Symbol
B
A
Service valve connection
(
gas side
)
M10-12×4 places
φ
20×2 places
Service valve connection
(
liquid side
)
φ
6.35
(
1
/
4"
)
(
Flare
)
Unit:mm
L2
Inlet
Outlet
Inlet
L3
L1
Service space
( )
L4
L2
L3
L4
L1
100 or more
80 or more
250 or more
280 or more
Terminal block
2-12×16
Slot hole
2-R
Installation space
63.4
390.6
390.6
69.4
111
.6
510
158.4
780
61.9
17.9
14.8
312.5
24.3
351.6
50.6
12
97.7
42.5
40°
40°
138.4
33.5
15.8
290
540
20
14.6
16.4
260
130
270
Center of gravity
Center of gravity
Notes
(
1
)
The unit must not be surrounded by walls on the four sides.
(
2
)
The unit must be fixed with anchor bolts.
An anchor bolt must not
protrude more than 15mm.
(
3
)
If the unit is installed in the location where there is a possibility of
strong winds, place the unit such that the direction of air from the
outlet gets perpendicular to the wind direction.
(
4
)
Leave 200mm or more space above the unit.
(
5
)
The wall height on the outlet side should be 1200mm or less.
(
6
)
The model name label is attached on the right side of the unit.
A
B
C
E
D
E
(2) Outdoor units
Models SRC20ZS-W, 25ZS-W, 35ZS-W
RCV000Z036
Содержание SRK 25ZS-W
Страница 20: ...19 18 SRK T 250 3 Remote control Unit mm 60 24 167 a Wireless remote control...
Страница 50: ...49 18 SRK T 250...
Страница 51: ...50 18 SRK T 250...
Страница 52: ...51 18 SRK T 250...
Страница 53: ...52 18 SRK T 250...
Страница 54: ...53 18 SRK T 250...
Страница 55: ...54 18 SRK T 250...
Страница 56: ...55 18 SRK T 250...
Страница 57: ...56 18 SRK T 250 2 Installation of outdoor unit RWC012A068...
Страница 58: ...57 18 SRK T 250...
Страница 59: ...58 18 SRK T 250...
Страница 60: ...59 18 SRK T 250...