11
-
'18 • SRK-T-250
RWA000Z274
Model
Item
SRK20ZS-WT
Indoor unit
SRK20ZS-WT
Outdoor unit
SRC20ZS-W
Power source
1 Phase, 220 - 240V, 50Hz / 220V, 60Hz
Operation
data
Nominal cooling capacity (range)
kW
2.0 ( 0.9 (Min.) - 2.9 (Max.))
Nominal heating capacity (range)
kW
2.7 ( 0.9 (Min.) - 4.3 (Max.))
Heating capacity (H2)
kW
—
Power consumption
Cooling
kW
0.44 ( 0.19 - 0.80 )
Heating
0.59 ( 0.20 - 1.40 )
Heating (H2)
—
Max power consumption
1.65
Running current
Cooling
A
2.6 / 2.5 / 2.4 (220/ 230/ 240V)
Heating
3.2 / 3.0 / 2.9 (220/ 230/ 240V)
Inrush current, max current
3.2 / 3.0 / 2.9 (220/ 230/ 240V)
Max.
9
Power factor
Cooling
%
79
Heating
85
EER
Cooling
4.55
COP
Heating
4.58
Heating (H2)
—
Sound power level
Cooling
dB(A)
48
56
Heating
50
56
Sound pressure level
Cooling
Hi: 34 Me: 25 Lo: 22 ULo: 19
45
Heating
Hi: 36 Me: 29 Lo: 23 ULo: 19
45
Silent mode sound pressure level
—
Cooling:43 / Heating:45
Exterior dimensions (Height x Width x Depth)
mm
290 x 870 x 230
540 x 780(+62) x 290
Exterior appearance
(Equivalent color : Munsell, RAL)
Titanium gray ( 1.6Y 6.59/0.63 ) , ( 7048 )
Black ( 4.0PB 2.44/0.25 ) , ( 9011 )
Stucco white
( 4.2Y 7.5/1.1 ) , ( 7044 )
Net weight
kg
9.5
31.0
Compressor type & Quantity
—
9RS102XDA21( Rotary type ) x 1
Compressor motor (Starting method)
kW
—
1.50 ( Inverter driven )
Refrigerant oil (Amount, type)
ℓ
—
0.32 ( FW50S )
Refrigerant (Type, amount, pre-charge length)
kg
R32 0.62 in outdoor unit (Incl. the amount for the piping of 15m )
Heat exchanger
0
M fins & inner grooved tubing
Refrigerant control
Capillary tubes + Electronic expansion valve
Fan type & Quantity
Tangential fan x 1
Propeller fan x 1
Fan motor (Starting method)
W
42 x1 (Direct drive)
24 x1 (Direct drive)
Air flow
Cooling
m
3
/min
Hi: 9.3 Me: 7.0 Lo: 5.9 ULo: 5.0
27.4
Heating
Hi: 10.0 Me: 8.5 Lo: 6.5 ULo: 5.9
23.6
Available external static pressure
Pa
0
0
Outside air intake
Not possible
—
Air filter, Quality / Quantity
Polypropylene net (Washable) x 2
—
Shock & vibration absorber
Rubber sleeve (for fan motor)
Rubber sleeve (for fan motor & compressor)
Electric heater
—
—
Operation
control
Remote control
Wireless-remote control
Room temperature control
Microcomputer thermostat
Operation display
RUN: Green , TIMER: Yellow
Safety equipments
Compressor overheat protection, Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection( High pressure control ), Cooling overload protection
Installation
data
Refrigerant piping size (O.D)
mm
Liquid line:
φ
6.35 (1/4") Gas line:
φ
9.52 (3/8")
Connecting method
Flare connection
Flare connection
Attached length of piping
m
Liquid line : 0.54 / Gas line : 0.47
—
Insulation for piping
Necessary ( Both sides ), independent
Refrigerant line (one way) length
m
Max.20
Vertical height diff. between O.U. and I.U.
m
Max.10 ( Outdoor unit is higher ) / Max.10 ( Outdoor unit is lower )
Drain hose
Hose connectable ( VP 16 )
Hole
φ
20 x 2 pcs
Drain pump, max lift height
mm
—
—
Recommended breaker size
A
16
L.R.A. (Locked rotor ampere)
A
3.2 / 3.0 / 2.9 (220/ 230/ 240V)
Interconnecting wires
Size x Core number
1.5mm
2
x 4 cores (Including earth cable) / Terminal block (Screw fixing type)
IP number
IPX0
IPX4
Standard accessories
Mounting kit, Clean filter ( Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1 )
Option parts
Interface kit ( SC-BIKN2-E )
The pipe length is 5m.
Notes (1) The data are measured at the following conditions.
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
(4) Select the breaker size according to the own national standard.
Item
Operation
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
ISO5151-T1
Heating
20˚C
—
7˚C
6˚C
ISO5151-H1
Heating (H2)
20˚C
—
2˚C
1˚C
ISO5151-H2
Содержание SRK 25ZS-W
Страница 20: ...19 18 SRK T 250 3 Remote control Unit mm 60 24 167 a Wireless remote control...
Страница 50: ...49 18 SRK T 250...
Страница 51: ...50 18 SRK T 250...
Страница 52: ...51 18 SRK T 250...
Страница 53: ...52 18 SRK T 250...
Страница 54: ...53 18 SRK T 250...
Страница 55: ...54 18 SRK T 250...
Страница 56: ...55 18 SRK T 250...
Страница 57: ...56 18 SRK T 250 2 Installation of outdoor unit RWC012A068...
Страница 58: ...57 18 SRK T 250...
Страница 59: ...58 18 SRK T 250...
Страница 60: ...59 18 SRK T 250...