1-10
Model SRK50A (Indoor unit)
SRC50HA (Outdoor unit)
Item
Model
SRK50A
SRC50HA
Cooling capacity
(1)
W
4500
Heating capacity
(1)
W
5700
Power source
1 Phase, 220/230/240V, 50Hz
Cooling input
kW
1.79
Running current (Cooling)
A
8.4/8.0/7.7
Heating input
kW
1.83
Running current (Heating)
A
8.5/8.1/7.9
Inrush current
A
39/41/42
COP (In cooling)
2.51
Cooling
Sound level
Hi : 44
Lo : 37
51
Noise level
Power level
dB
Hi : 58
Lo : 51
65
Heating
Sound level
Hi : 45
Lo : 38
53
Power level
Hi : 59
Lo : 52
67
Exterior dimensions
Height x Width x Depth
mm
298
‚
798
‚
203
640
‚
850
‚
290
Color
Stucco white
Stucco white
Net weight
kg
10
45
Refrigerant equipment
Compressor type & Q’ty
–
RM5523GNE4 (Rotary type) x 1
Motor
kW
–
1.7
Starting method
–
Line starting
Heat exchanger
Louver fins & grooved tubing
Refrigerant control
Capillary tubes
Refrigerant
(3)
kg
R22 1.45
Refrigerant oil
R
0.7 (BARREL FREEZE 32SAM)
Defrost control
MC control
Air handling equipment
Fan type & Q’ty
Tangential fan x 1
Propeller fan x 1
Motor
W
23
35
Air flow (at High)
(Cooling)
11
39
(Heating)
CMM
13
39
Air filter, Q’ty
Polypropylene net (washable) x 2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Operation control
Operation switch
Wireless–Remote controller
–
Room temperature control
MC. Thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow),
–
ECONO (Orange), HI POWER (Green)
Safety equipment
–
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
O.D
mm(in)
Liquid line: ø6.35 (1/4")
Gas line: ø12.7 (1/2")
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.5m Gas line: 0.43m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
3m (3 cores with Earth)
Connection
Size x Core number
1.5mm
2
x 5 cores (With Earth)
wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Optional parts
–
Notes (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
ISO-T1, JIS C9612
Heating
20ºC
–
7ºC
6ºC
ISO-T1, JIS C9612
(2) The operation data are applied to the 220V, 230V or 240V districts respectively
(3) The refrigerant quantity to be charged includes the refrigerant in 7 m connecting piping. (Purging is not required even in the short piping.)
If the piping length is longer. (When it is 7 to 15 m, add 20 g refrigerant per meter.)
(4) When the unit is operated in cooling or dehumidification mode at the outside air temperature of 1ºC and less, there is a possibility that water leakage
occurs at the indoor unit.
Operation data
(1)
Refrigerant
piping