1-19
Model SRK50A (Indoor unit)
SRC50CA (Outdoor unit)
(2) The operation data are applied to the 220V, 230V or 240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, (When it is 7 to 15 m, add 20 g refrigerant per meter.)
(4) When the unit is operated in cooling or dehumidification mode at the outside air temperature of 1ºC and less, there is a possibility that water leakage
occurs at the indoor unit.
Notes (1) The data are measured at the following conditions.
Item
Model
SRK50A
SRC50CA
Cooling capacity
(1)
W
4500
Power source
1 Phase, 220/230/240V, 50 Hz
Cooling input
kW
1.79
Running current (Cooling)
A
8.4/8.0/7.7
Inrush current
A
39/41/42
COP (In cooling)
2.51
Noise level
Sound level
dB
Hi : 44 Lo : 37
51
Power level
Hi : 58 Lo : 51
65
Exterior dimensions
mm
298
×
798
×
203
640
×
850
×
290
Height
×
Width
×
Depth
Color
Noble white
Stucco white
Net weight
kg
10
44
Refrigerant equipment
–
RM5523GNE4 (Rotary type)
×
1
Compressor types & Q’ty
Motor
kW
–
1.7
Starting method
–
Line starting
Heat exchanger
Louver fins & grooved tubing
Refrigerant control
Capillary tubes
Refrigerant
(3)
kg
R22 1.45
Refrigerant oil
R
0.7 (BARREL FREEZE 32SAM)
Air handling equipment
Tangential fan
×
1
Propeller fan
×
1
Fan type & Q’ty
Motor
W
23
35
Air flow (at High)
CMM
11
39
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Wireless-Remote controller
–
Operation switch
Room temperature control
MC. Thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow),
–
ECONO (Orange), HI POWER (Green)
Safety equipment
–
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
O.D
mm (in)
Liquid line:
φ
6.35 (1/4") Gas line:
φ
12.7 (1/2")
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.5m
–
Gas line : 0.43m
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
3 m (3 cores with Earth)
Size
×
Core number
1.5 mm
2
×
3 cores (Including earth cable)
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Optional parts
–
Connection
wiring
Operation data
(1)
Refrig
erant
piping
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27
°
C
19
°
C
35
°
C
24
°
C
ISO-T1, JIS C9612