background image

 

A-4

 

Revisions

 

*The manual number is noted at the lower right of the top cover. 

Print Date 

*Manual Number 

Revision 

Sep., 2000  IB(NA)-0800145-A  First edition 

Mar., 2001  IB(NA)-0800145-B 

 

 

Model addition 

QJ72LP25G 

May, 2004  IB(NA)-0800145-C 

 

Partial correction 

SAFETY PRECAUTIONS, Compliance 
with the EMC Directive and the Low 
Voltage Directive, Chapter 2, Section 3.1, 
Chapter 4 (a), (b), (1), Chapter 5, 6 

Aug., 2004  IB(NA)-0800145-D 

 

Partial correction 

SAFETY PRECAUTIONS,  
Chapter 1, 2, 3, 4, 5, 6 

Jan., 2005  IB(NA)-0800145-E 

 

Partial correction 

Compliance with the EMC Directive and 
the Low Voltage Directive,  
Chapter 1, 2, 3, 6 

Nov., 2005  IB(NA)-0800145-F 

 

Partial correction 

Compliance with the EMC Directive and 
the Low Voltage Directive, Chapter 4 

Mar., 2006  IB(NA)-0800145-G 

 

Partial correction 

Chapter 2, 4 

Mar., 2007  IB(NA)-0800145-H 

 

Change of a term  

“PLC” was changed to “Programmable 
controller” 

 

Partial correction 

SAFETY PRECAUTIONS, Chapter 3, 4, 5 

Sep., 2008 

IB(NA)-0800145-I 

 

Partial correction 

SAFETY PRECAUTIONS, Compliance 
with the EMC Directive and the Low 
Voltage Directive, Chapter 2, 4, 5, 6 

 

 

 

 

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses.  Mitsubishi Electric Corporation cannot 
be held responsible for any problems involving industrial property rights which 
may occur as a result of using the contents noted in this manual. 

©

  2000  MITSUBISHI ELECTRIC CORPORATION 

 

Содержание QJ72BR15

Страница 1: ...you for purchasing the Mitsubishi programmable controller MELSEC Q Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL NET H...

Страница 2: ...autions on the programmable controller system refer to the CPU User s Manual In this manual the safety instructions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardo...

Страница 3: ...specified torque range Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage to the screw or module z Completely turn...

Страница 4: ...r fasten them using a clamp If the cables are not placed in a duct or not fastened with a clamp their positions may become unstable and may move or they may be pulled inadvertently This may damage the...

Страница 5: ...05 IB NA 0800145 F Partial correction Compliance with the EMC Directive and the Low Voltage Directive Chapter 4 Mar 2006 IB NA 0800145 G Partial correction Chapter 2 4 Mar 2007 IB NA 0800145 H Change...

Страница 6: ...A 5 CONTENTS 1 Overview 1 2 Performance Specifications 2 3 Handling 6 3 1 Module Handling Precautions 6 4 Part Identification Names 7 5 Wiring 10 6 External Dimensions 11...

Страница 7: ...m meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi programmable controller EMC and Low Voltage Directives compliant into other machinery or equipment re...

Страница 8: ...rm that any of the following products is enclosed Model name Part name Quantity QJ72LP25 25 QJ72LP25 25 MELSECNET H Network Module optical loop type 1 QJ72LP25G QJ72LP25G MELSECNET H Network Module op...

Страница 9: ...B 8 2 LW 2000 bytes Maximum I O points per remote I O station X Y 4096 points If the X Y numbers are duplicate only one side is taken into consideration Communication speed 25Mbps 10Mbps selected with...

Страница 10: ...determined according to the type of cable Refer to the Q Corresponding MELSECNET H Network System Reference Manual Remote I O network for details 4 Specialized skill and specific tools are required to...

Страница 11: ...I O station X Y 4096 points If the X Y numbers are duplicate only one side is taken into consideration Communication speed 10 Mbps Communication method Token bus Synchronization method Frame synchron...

Страница 12: ...g determined according to the type of cable and number of stations Refer to the Q Corresponding MELSECNET H Network System Reference Manual Remote I O network for details 4 When creating a multiplexed...

Страница 13: ...d torque range Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage to the screw or module z Completely turn off the...

Страница 14: ...n 1 LED indicator section 1 in this chapter 2 RS 232 connector 5 RESET switch 1 3 Station number setting switches 2 a in this chapter 6 Coaxial connector 3 in this chapter 4 Mode setting switch 2 b in...

Страница 15: ...QJ72LP25 25 and QJ72BR15 whose first five digits of the serial number is 02112 or later 2 When a remote I O module is used in a redundant power supply system the REM LED and ERR LED indicate errors as...

Страница 16: ...return test 2 Internal self return test 3 Hardware test 10Mbps used 4 Online 5 Self return test 6 Internal self return test 7 Hardware test 25Mbps used 8 to F Prohibited 2 QJ72LP25G QJ72BR15 Setting...

Страница 17: ...o malfunction because of faulty cable connections z When disconnecting a communication cable do not pull it by holding the cable part To disconnect the cable hold its connector that is plugged into th...

Страница 18: ...11 6 External Dimensions 1 QJ72LP25 25 QJ72LP25G 90 3 54 1 27 4 98 3 86 1 08 4 23 0 91 0 16 1 Please contact your nearest Mitsubishi Electric System Service Corporation for detail Unit mm in...

Страница 19: ...12 2 QJ72BR15 90 3 54 55 27 4 98 3 86 0 5 8 3 7 2 0 5 8 3 7 2 0 8 D 5 C 4 9 1 RS 232 MODE RESET Q J72B R15 STATION X10 X1 NO 2 17 1 08 Unit mm in...

Страница 20: ...s Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industri...

Отзывы: