background image

 

Warranty 

Mitsubishi will not be held liable for damage caused by factors found not to be the cause of 
Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, 
secondary damage, accident compensation caused by special factors unpredictable by 
Mitsubishi; damages to products other than Mitsubishi products; and to other duties. 

For safe use 

 

y

 This product has been manufactured as a general-purpose part for general industries, and 

has not been designed or manufactured to be incorporated in a device or system used in 
purposes related to human life.  

 

y

 Before using the product for special purposes such as nuclear power, electric power, 

aerospace, medicine or passenger movement vehicles, consult with Mitsubishi. 

 

y

 This product has been manufactured under strict quality control. However, when installing 

the product where major accidents or losses could occur if the product fails, install 
appropriate backup or failsafe functions in the system. 

 

U.S.A 

Mitsubishi Electric Automation Inc.

 

500 Corporate Woods Parkway Vernon 

 

Hills, IL 60061, U.S.A.

 Tel 

+1-847-478-2100

Brazil   

MELCO-TEC Rep. Com.e Assessoria 

 Tecnica 

Ltda.

 

Rua Correia Dias, 184, 

 

Edificio Paraiso Trade Center-8 andar 

 

Paraiso, Sao Paulo, SP Brazil

 Tel 

+55-11-5908-8331

Germany   

Mitsubishi Electric Europe B.V. German 

 Branch
 

Gothaer Strasse 8 D-40880 Ratingen, 

 GERMANY
 Tel 

+49-2102-486-0

U.K 

Mitsubishi Electric Europe B.V. UK 

 Branch
 

Travellers Lane, Hatfield, Hertfordshire., 

 AL10 

8XB, 

U.K.

 Tel 

+44-1707-276100

Italy 

Mitsubishi Electric Europe B.V. Italian 

 Branch
 

Centro Dir. Colleoni, Pal. Perseo-Ingr.2

 

Via Paracelso 12, I-20041 Agrate Brianza., 

 Milano, 

Italy

 Tel 

+39-039-60531

Spain   

Mitsubishi Electric Europe B.V. Spanish 

 Branch
 

Carretera de Rubi 76-80,

 

E-08190 Sant Cugat del Valles, 

 Barcelona, 

Spain

 Tel 

+34-93-565-3131

France   

Mitsubishi Electric Europe B.V. French 

 Branch
 

25, Boulevard des Bouvets, F-92741 

 

Nanterre Cedex, France

 TEL: 

+33-1-5568-5568

South Africa  

Circuit Breaker Industries Ltd.

 

Private Bag 2016, ZA-1600 Isando, 

 South 

Africa

 Tel 

+27-11-928-2000

Hong Kong  

Mitsubishi Electric Automation 

 

(Hong Kong) Ltd.

 

10th Floor, Manulife Tower, 169 Electric

 

Road, North Point, Hong Kong

 Tel 

+852-2887-8870

China Mitsubishi 

Electric 

Automation 

 (Shanghai) 

Ltd.

 

4/F Zhi Fu Plazz, No.80 Xin Chang Road,

 Shanghai 

200003, 

China

 Tel 

+86-21-6120-0808

Taiwan   

Setsuyo Enterprise Co., Ltd.

 

6F No.105 Wu-Kung 3rd.Rd, Wu-Ku 

 

Hsiang, Taipei Hsine, Taiwan

 Tel 

+886-2-2299-2499

Korea   

Mitsubishi Electric Automation Korea 

 Co., 

Ltd.

 

1480-6, Gayang-dong, Gangseo-ku 

 

Seoul 157-200, Korea

 Tel 

+82-2-3660-9552

Singapore 

Mitsubishi Electric Asia Pte, Ltd.

 

307 Alexandra Road #05-01/02, 

 Mitsubishi 

 

Electric Building, 

 Singapore 

159943

 Tel 

+65-6470-2460

Thailand   

Mitsubishi Electric Automation (Thailand) 

 Co., 

Ltd.

 

Bang-Chan Industrial Estate No.111 

 

Moo 4, Serithai Rd, T.Kannayao, 

 

A.Kannayao, Bangkok 10230 Thailand

 Tel 

+66-2-517-1326

Indonesia 

P.T. Autoteknindo Sumber Makmur

 

Muara Karang Selatan, Block A/Utara 

 

No.1 Kav. No.11 Kawasan Industri 

 

Pergudangan Jakarta - Utara 14440, 

 

P.O.Box 5045 Jakarta, 11050 Indonesia

 Tel 

+62-21-6630833

India   

Messung Systems Pvt, Ltd.

 

Electronic Sadan NO:III Unit No15, 

 

M.I.D.C Bhosari, Pune-411026, India

 Tel 

+91-20-2712-3130

Australia   

Mitsubishi Electric Australia Pty. Ltd.

 

348 Victoria Road, Rydalmere, 

 

N.S.W 2116, Australia

 Tel 

+61-2-9684-7777

Country/Region Sales office/Tel

When exported from Japan, this manual does not require application to the Ministry 

of Economy, Trade and Industry for service transaction permission.

Specifications subject to change without notice.

Printed in Japan on recycled paper.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

Country/Region Sales office/Tel

 

Содержание QJ72BR15

Страница 1: ...you for purchasing the Mitsubishi programmable controller MELSEC Q Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL NET H...

Страница 2: ...autions on the programmable controller system refer to the CPU User s Manual In this manual the safety instructions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardo...

Страница 3: ...specified torque range Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage to the screw or module z Completely turn...

Страница 4: ...r fasten them using a clamp If the cables are not placed in a duct or not fastened with a clamp their positions may become unstable and may move or they may be pulled inadvertently This may damage the...

Страница 5: ...05 IB NA 0800145 F Partial correction Compliance with the EMC Directive and the Low Voltage Directive Chapter 4 Mar 2006 IB NA 0800145 G Partial correction Chapter 2 4 Mar 2007 IB NA 0800145 H Change...

Страница 6: ...A 5 CONTENTS 1 Overview 1 2 Performance Specifications 2 3 Handling 6 3 1 Module Handling Precautions 6 4 Part Identification Names 7 5 Wiring 10 6 External Dimensions 11...

Страница 7: ...m meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi programmable controller EMC and Low Voltage Directives compliant into other machinery or equipment re...

Страница 8: ...rm that any of the following products is enclosed Model name Part name Quantity QJ72LP25 25 QJ72LP25 25 MELSECNET H Network Module optical loop type 1 QJ72LP25G QJ72LP25G MELSECNET H Network Module op...

Страница 9: ...B 8 2 LW 2000 bytes Maximum I O points per remote I O station X Y 4096 points If the X Y numbers are duplicate only one side is taken into consideration Communication speed 25Mbps 10Mbps selected with...

Страница 10: ...determined according to the type of cable Refer to the Q Corresponding MELSECNET H Network System Reference Manual Remote I O network for details 4 Specialized skill and specific tools are required to...

Страница 11: ...I O station X Y 4096 points If the X Y numbers are duplicate only one side is taken into consideration Communication speed 10 Mbps Communication method Token bus Synchronization method Frame synchron...

Страница 12: ...g determined according to the type of cable and number of stations Refer to the Q Corresponding MELSECNET H Network System Reference Manual Remote I O network for details 4 When creating a multiplexed...

Страница 13: ...d torque range Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage to the screw or module z Completely turn off the...

Страница 14: ...n 1 LED indicator section 1 in this chapter 2 RS 232 connector 5 RESET switch 1 3 Station number setting switches 2 a in this chapter 6 Coaxial connector 3 in this chapter 4 Mode setting switch 2 b in...

Страница 15: ...QJ72LP25 25 and QJ72BR15 whose first five digits of the serial number is 02112 or later 2 When a remote I O module is used in a redundant power supply system the REM LED and ERR LED indicate errors as...

Страница 16: ...return test 2 Internal self return test 3 Hardware test 10Mbps used 4 Online 5 Self return test 6 Internal self return test 7 Hardware test 25Mbps used 8 to F Prohibited 2 QJ72LP25G QJ72BR15 Setting...

Страница 17: ...o malfunction because of faulty cable connections z When disconnecting a communication cable do not pull it by holding the cable part To disconnect the cable hold its connector that is plugged into th...

Страница 18: ...11 6 External Dimensions 1 QJ72LP25 25 QJ72LP25G 90 3 54 1 27 4 98 3 86 1 08 4 23 0 91 0 16 1 Please contact your nearest Mitsubishi Electric System Service Corporation for detail Unit mm in...

Страница 19: ...12 2 QJ72BR15 90 3 54 55 27 4 98 3 86 0 5 8 3 7 2 0 5 8 3 7 2 0 8 D 5 C 4 9 1 RS 232 MODE RESET Q J72B R15 STATION X10 X1 NO 2 17 1 08 Unit mm in...

Страница 20: ...s Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industri...