6
3
SPECIFICATIONS
Item
Service Ref
PUMY-125VM
PUMY-71VM
Unit
Standard performance
Heating Cooling
Rated Cooling capacity
Rated power consumption
Operating current
Operating power factor
Starting current
Rated Heating capacity
Rated power consumption
Operating current
Operating power factor
Starting current
Rated power supply
Type
o
charge amount
Control method
External finish (Munsell colour-coded markings)
Dimensions H
o
W
o
D (Note 1)
Heat exchanger type
Defrost method
Pressure gauge
Noise level
Weight
Refrigerant pipe size
Refrigerant
Model
Type
o
quantity
Starting method
Motor output
Capacity control
Daily cooling capacity
Heater <crankcase>
Refrigerating oil (Model)
Type
o
quantity
Airflow
Motor output
High pressure protection
Compressor protection
Blower protection
Frequency converter circuit
Compressor
Protection
devices
Gas
Liquid
Fan
kcal/h
kW
A
%
A
kcal/h
kW
A
%
A
mm
kW
%
Legal tons
W
L
k
/min
W
dB
kg
[
mm
[
mm
kg
7,100
3.50
17.5-16.7-16.0
91
15.0
8,000
3.65
18.2-17.4-16.7
91
15.0
12,500
6.57
34.9-33.5-32.2
85
22.0
14,000
6.10
32.6-31.2-29.9
85
22.0
Single phase 220-230-240V 50Hz
Molten-galvanized steel plate (with polyester coating), ivory white <5Y 8/1>
1280
o
900
o
320 (+30) 1280
o
1020
o
350 (+30)
Crossover fin
Fully enclosed type
o
1
Frequency converter start
Propeller (direct)
o
2
Reverse cycle
—
High pressure pressure sensor (3.0MPa)
Thermal switch
Thermal switch
Overheating, Over current protection
Expansion valve
CHV253FAA
2.6
Cooling 27-100% Heating 24-100%
1.1 (110Hz)
25-28-30
1.07 (MS56)
95
40
o
2
52
93
15.88
9.52
R22
o
5
EHV46FAA
3.5
Cooling 27-100% Heating 25-100%
1.9 (104Hz)
38-41-45
1.4 (MS32)
90
60
o
2
54
130
19.05
9.52
R22
o
8.5
Note 1: External dimensions in parentheses indicate the dimensions of protruding parts.
Note 2: Rating conditions (JIS B 8615)
Cooling : Indoor
: D.B. 27
:
W.B. 19.5
:
: Outdoor : D.B. 35
:
W.B. 24
:
Heating : Indoor
: D.B. 21
:
: Outdoor : D.B. 7
:
W.B. 6
:
OC183E--1.qxp 10.5.6 2:04 PM Page 6