4-3. LOCKING THE OPERATION MODE OF THE AIR CONDITIONER (COOL, DRY, HEAT)

4-4. LOWERING THE OPERATION NOISE OF THE OUTDOOR UNIT

4-2. GAS CHARGE

Perform

 

gas

 

charge

 

to

 

unit.

Connect

 

gas

 

cylinder

 

to

 

the

 

service

 

port

 

of

 

stop

 

valve.

2) 

Perform

 

air

 

purge

 

of

 

the

 

pipe

 

(or

 

hose)

 

coming

 

from

 

refrigerant

 

gas

 

cylinder.

3) Replenish specified amount of the refrigerant, while operating the air condi-

tioner

 

for

 

cooling.

Note:

In case of adding refrigerant, comply with the quantity specified for the refrigera -

ing

 

cycle.

CAUTION:

When

 

charging

 

the

 

refrigerant

 

system

 

with

 

additional

 

refrigerant,

 

be

 

sure

 

to

 

use

 

liquid

 

refrigerant.

 

Adding

 

gas

 

refrigerant

 

may

 

change

 

the

 

composition

 

of

 

the

 

refrigerant

 

in

 

the

 

system

 

and

 

affect

 

normal

 

operation

 

of

 

the

 

air

 

conditioner.

 

Also,

 

charge

 

the

 

liquid

 

refrigerant

 

slowly,

 

otherwise

 

the

 

compressor

 

will

 

be

 

locked.

To

 

maintain

 

the

 

high

 

pressure

 

of

 

the

 

gas

 

cylinder,

 

warm

 

the

 

gas

 

cylinder

 

with

 

warm water (under 40°C) during cold season. But never use naked 

fi

re or steam.

• 

Description

 

of

 

the

 

function:

 

With

 

this

 

function,

 

once

 

the

 

operation

 

mode

 

is

 

locked

 

to

 

either

 

COOL/DRY

 

mode

 

or

 

HEAT

 

mode,

 

the

 

air

 

conditioner

 

operates

 

in

 

that

 

mode

 

only.

Changing

 

the

 

setting

 

is

 

required

 

to

 

activate

 

this

 

function.

 

Please

 

explain

 

about

 

this

 

function

 

to

 

your

 

customers

 

and

 

ask

 

them

 

whether

 

they

 

want

 

to

 

use

 

it.

[How to lock the operation mode]

Be

 

sure

 

to

 

turn

 

off

 

the

 

main

 

power

 

for

 

the

 

air

 

conditioner

 

before

 

making

 

the

 

setting.

2) 

Set

 

the

 

 

of

 

SW

 

on

 

the

 

outdoor

 

controller

 

board

 

to

 

ON

 

to

 

enable

 

this

 

func-

tion.

3) 

To

 

lock

 

the

 

operation

 

mode

 

in

 

COOL/DRY

 

mode,

 

set

 

the

 

“2”

 

of

 

SW

 

on

 

the

 

outdoor

 

controller

 

board

 

to

 

OFF.

 

To

 

lock

 

the

 

operation

 

in

 

HEAT

 

mode,

 

set

 

the

 

same

 

switch

 

to

 

ON.

4) 

Turn

 

on

 

the

 

main

 

power

 

for

 

the

 

air

 

conditioner.

• 

Description

 

of

 

the

 

function:

 

With

 

this

 

function,

 

the

 

operating

 

noise

 

of

 

the

 

outdoor

 

unit

 

can

 

be

 

lowered

 

by

 

reducing

 

the

 

operation

 

load,

 

for

 

example,

 

during

 

nighttime

 

in

 

COOL

 

mode.

 

However,

 

please

 

note

 

that

 

the

 

cooling

 

and

 

heating

 

capacity

 

may

 

lower

 

if

 

this

 

function

 

is

 

activated.

Changing

 

the

 

setting

 

is

 

required

 

to

 

activate

 

this

 

function.

 

Please

 

explain

 

about

 

this

 

function

 

to

 

your

 

customers

 

and

 

ask

 

them

 

whether

 

they

 

want

 

to

 

use

 

it.

4-5. CHANGING THE AMPERE LIMIT

• 

Description

 

of

 

the

 

function:

  With this function, the amount of current that flows in the outdoor unit can be 

changed.

Note:

Use

 

this

 

function

 

only

 

when

 

the

 

amount

 

of

 

current

 

exceeds

 

the

 

allowed

 

value.

[How to change the ampere limit]

Be

 

sure

 

to

 

turn

 

off

 

the

 

main

 

power

 

for

 

the

 

air

 

conditioner

 

before

 

making

 

the

 

setting.

2) 

Make

 

the

 

setting

 

referring

 

to

 

the

 

table

 

below.

3) 

Turn

 

on

 

the

 

main

 

power

 

for

 

the

 

air

 

conditioner.

Lower

 

the

 

operating

 

noise

[How to lower the operating noise]

Be

 

sure

 

to

 

turn

 

off

 

the

 

main

 

power

 

for

 

the

 

air

 

conditioner

 

before

 

making

 

the

 

setting.

2) 

Set

 

the

 

“3”

 

of

 

SW

 

on

 

the

 

outdoor

 

controller

 

board

 

to

 

ON

 

to

 

enable

 

this

 

func-

tion.

3) 

Turn

 

on

 

the

 

main

 

power

 

for

 

the

 

air

 

conditioner.

Union

Stop

 

valve

Liquid

 

pipe

Indoor

 

unit

Stop

 

valve

 

with

 

service

 

port

Gas

 

pipe

Refrigerant

 

gas

            

cylinder

  

operating

 

valve

(for

 

R4

0A)

Gauge

 

manifold

 

valve

 

(for

 

R4

0A)

Charge

 

hose

 

(for

 

R4

0A)

Refrigerant

 

gas

 

cylinder

 

for

 

R4

0A

 

with

 

siphon

Electronic

 

scale

 

for

 

refrigerant

 

charging

Refrigerant

 

(liquid)

Outdoor

 

unit

*

 

E

 

unit

 

is

 

for

 

5D

02VA

 

only.

Union

Union
Union

HEAT

COOL/DRY

SW2

MXZ-5D

02VA

MXZ-4D83VA

0.5

 

A

0.5

 

A

5.5

 

A

5.5

 

A

Factory

 

setting

Full

Factory

 

setting

Full

JG79A662H01_en.indd   6

2012/09/24 (月)   午後 7:00:11

Содержание MXZ-4D83VA

Страница 1: ...e dell unit esterna Per l installazione dell unit interna fare riferimento al relativo manuale di instal lazione Manual de Instala o Para o INSTALADOR Este manual descreve apenas a instala o da unidad...

Страница 2: ...e ventilation in accord ance with EN378 1 n Check that the refrigerant gas does not leak after installation has been completed If refrigerant gas leaks indoors and comes into contact with the flame of...

Страница 3: ...ibility of becoming short cycle install an outlet guide and make sure there is enough space behind of the unit When installing two or more units do not install the units in front or behind each other...

Страница 4: ...200 mm 2 U shape notched holes Base bolt M10 320 mm 2 12 mm 36 mm oval holes Base bolt M10 355 mm 387 mm After the leak test apply insulat ing material tightly so that there is no gap When the piping...

Страница 5: ...necting section of the terminal block 3 Firmly tighten the terminal screws to prevent them from loosening Af ter tightening pull the wires lightly to confirm that they do not move 4 Perform 2 and 3 fo...

Страница 6: ...y hold copper pipe in the dimension shown in the table Select A mm from the table according to the tool selected 5 Check Compare the flared work with Fig 6 If flare is noted to be defective cut off th...

Страница 7: ...ller board to OFF To lock the operation in HEAT mode set the same switch to ON 4 Turn on the main power for the air conditioner Description of the function With this function the operating noise of th...

Страница 8: ...board damage To prevent electronic control P C board damage make sure to perform static elimi nation before operating this function This function does not operate when the outside temperature is 0 C...

Страница 9: ...a plaque du produit Opmerking het serienummer staat op het naamplaatje van het product Nota El n mero de serie se encuentra en la placa que contiene el nombre del producto Nota il numero di serie si t...

Отзывы: