5. PARAMETERS
5 - 1
5. PARAMETERS
CAUTION
Never make a drastic adjustment or change to the parameter values as doing so
will make the operation unstable.
Do not change the parameter settings as described below. Doing so may cause
an unexpected condition, such as failing to start up the servo amplifier.
Changing the values of the parameters for manufacturer setting
Setting a value out of the range
Changing the fixed values in the digits of a parameter
When you write parameters with the controller, make sure that the identification
No. of the servo amplifier is set correctly. Otherwise, the parameter settings of
another identification No. may be written, possibly causing the servo amplifier to
be an unexpected condition.
5.1 List of communication-related parameters
POINT
To enable a parameter whose symbol is preceded by *, cycle the power after
setting it. However, the time will be longer depending on a setting value of [Pr.
PF25 Instantaneous power failure tough drive - Detection time] when
"instantaneous power failure tough drive selection" is enabled in [Pr. PA20].
The following parameters cannot be used with CC-Link IE Field Network Basic
communication.
[Pr. PN10 Ethernet communication time-out selection]
[Pr. PN23 KeepAlive time]
No. Symbol
Name
Initial
value
Unit
PN01
For manufacturer setting
0h
PN02 CERT Communication
error
detection time
1000 ms
[ms]
PN03
For manufacturer setting
0000h
PN04
0000h
PN05
0000h
PN06
0000h
PN07
0000h
PN08
0000h
PN09
1
PN10
EIC
Ethernet communication time-out selection
0
[s]
PN11
*IPAD1 IP address setting 1
192
PN12
*IPAD2 IP address setting 2
168
PN13
*IPAD3 IP address setting 3
3
PN14
*IPAD4 IP address setting 4
0
PN15
*SNMK1 Subnet mask setting 1
255
PN16
*SNMK2 Subnet mask setting 2
255
PN17
*SNMK3 Subnet mask setting 3
255
PN18
*SNMK4 Subnet mask setting 4
0
PN19
*DGW1 Default gateway setting 1
192
PN20
*DGW2 Default gateway setting 2
168
PN21
*DGW3 Default gateway setting 3
3
PN22
*DGW4 Default gateway setting 4
1
PN23 *KAA KeepAlive
time
3600 [s]