![Mitsubishi MR-JE-100B Скачать руководство пользователя страница 258](http://html1.mh-extra.com/html/mitsubishi/mr-je-100b/mr-je-100b_instruction-manual_1808431258.webp)
11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 45
11.12 EMC filter (recommended)
POINT
For when multiple servo amplifiers are connected to one EMC filter, refer to
section 6.4 of "EMC Installation Guidelines".
It is recommended that one of the following filters be used to comply with EN EMC directive. Some EMC
filters have large in leakage current.
(1) Combination with the servo amplifier
Servo amplifier
Recommended filter (Soshin Electric)
Mass [kg]
Model
Rated current
[A]
Rated voltage [V
AC]
Leakage current
[mA]
MR-JE-10B to
MR-JE-100B
HF3010A-UN (Note)
10
250 5
3.5
MR-JE-200B,
MR-JE-300B
HF3030A-UN (Note)
30 5.5
Note. A surge protector is separately required to use any of these EMC filters.
(2) Connection example
(a) For 3-phase 200 V AC to 240 V AC power supply
MCCB
Servo amplifier
1
2
3
(Note)
Surge protector
(RSPD-250-U4)
(OKAYA Electric Industries Co., Ltd.)
3-phase
200 V AC to 240 V AC
1
2
3
MC
EMC filter
L1
L2
L3
4
5
6
E
Note. The example is when a surge protector is connected.