![Mitsubishi MR-JE-100B Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/mitsubishi/mr-je-100b/mr-je-100b_instruction-manual_1808431184.webp)
7. SPECIAL ADJUSTMENT FUNCTIONS
7 - 21
(b) Return time constant disabled was selected.
The gain switching time constant is enabled. The time constant is disabled at gain return.
The following example shows for [Pr. PB26 (CDP)] = 0201, [Pr. PB27 (CDL)] = 0, and [Pr. PB28
(CDT)] = 100 [ms].
ON
CDP (Gain switching)
After-switching gain
Before-switching gain
Switching at [Pr. PB28 (CDT)] = 100 [ms] only when gain switching on (when switching)
CDT = 100 ms
Return time constant disabled
Switching at 0 ms
OFF
OFF
63.4%
Gain switching