![Mitsubishi MR-JE-100B Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/mitsubishi/mr-je-100b/mr-je-100b_instruction-manual_1808431113.webp)
5. PARAMETERS
5 - 18
5.2.2 Gain/filter setting parameters ([Pr. PB_ _ ])
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
PB01
FILT
Adaptive tuning mode (adaptive filter II)
Set the adaptive tuning.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x
Filter tuning mode selection
Select the adjustment mode of the machine resonance suppression
filter 1. Refer to section 7.1.2 for details.
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
Tuning accuracy selection
0: Standard
1: High accuracy
The frequency is estimated more accurately in the high accuracy
mode compared to the standard mode. However, the tuning sound
may be larger in the high accuracy mode.
This digit is available with servo amplifier with software version C5
or later.
0h
PB02
VRFT
Vibration suppression control tuning mode (advanced vibration suppression control II)
Set the vibration suppression control tuning. Refer to section 7.1.5 for details.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x
Vibration suppression control 1 tuning mode selection
Select the tuning mode of the vibration suppression control 1.
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ _ x _
Vibration suppression control 2 tuning mode selection
Select the tuning mode of the vibration suppression control 2. To
enable the digit, select "3 inertia mode (_ _ _ 1)" of "Vibration
suppression mode selection" in [Pr. PA24 Function selection A-4].
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ x _ _
For manufacturer setting
0h
x _ _ _
0h
PB03 TFBGN Torque feedback loop gain
Set a torque feedback loop gain in the continuous operation to torque control mode.
Decreasing the setting value will also decrease a collision load during continuous operation to
torque control mode.
Setting a value of 6 rad/s or smaller will apply 6 rad/s.
18000
[rad/s]
0 to
18000
PB04
FFC
Feed forward gain
Set the feed forward gain.
When the setting is 100%, the droop pulses during operation at constant speed are nearly
zero. However, sudden acceleration/deceleration will increase the overshoot. As a guideline,
when the feed forward gain setting is 100%, set 1 s or longer as the acceleration time constant
up to the rated speed.
0
[%]
0 to 100