 SAFETY PRECAUTIONS 

(Read these precautions before using.)

When using Mitsubishi equipment, thoroughly read this manual and the
associated manuals introduced in this manual. Also pay careful attention to
safety and handle the module properly.
These SAFETY PRECAUTIONS classify the safety precautions into two
categories: “DANGER” and “CAUTION”.

DANGER

CAUTION

Procedures which may lead to a dangerous condition and
cause death or serious injury, if not carried out properly.

Procedures which may lead to a dangerous condition and
cause superficial to medium injury, or physical damage
only, if not carried out properly.

Depending on circumstances, procedures indicated by 

 CAUTION may also

be linked to serious results.
In any case, it is important to follow the directions for usage.

Store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.

[DESIGN PRECAUTIONS]

 DANGER

 Do not write data to the "read-only area" in the buffer memory of the

intelligent function module.
Do not turn on/off the "reserved" signals among the I/O signals to/from the
PLC CPU.
Doing so can malfunction the PLC system.

 Depending on the malfunction of the external output transistor, there may

be cases where the output is ON or OFF status. Install external monitoring
circuitry for output signals that may lead to major accidents.

 CAUTION

 Do not bunch the control wires or communication cables with the main

circuit or power wires, or install them close to each other.
They should be installed 100 mm(3.94 inch) or more from each other.
Not doing so could result in noise that may cause malfunction.

Содержание MELSEC-Q Q64TCTT

Страница 1: ...4TCTT Q64TCTTBW Thank you for purchasing the Mitsubishi general purpose programmable logic controller MELSEC Q series Prior to use please read this manual thoroughly and familiarize yourself with the...

Страница 2: ...any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECA...

Страница 3: ...or the module resulting in fallout short circuits or malfunction Switch all phases of the external power supply off when mounting or removing the module Not ding so may cause electric shock or damage...

Страница 4: ...as the terminal layout Fire or failure may result if incorrect voltage is input or incorrect wiring is performed Connecting terminals with incorrect voltage may result in malfunction or mechanical fa...

Страница 5: ...ary manuals Detailed manual Manual Name Manual Number Model Code Q64TCTT Q64TCTTBW Q64TCRT Q64TCRTBW type Temperature Control Module User s Manual details SH 080108 13JT11 Conformance to the EMC Direc...

Страница 6: ...dth 0 7 Ambient temperature 0 C to 55 C Within 1 0 C Ambient temperature 100 C to 150 C Within 2 0 C Cold junction temperature compensatio n accuracy Ambient temperature 150 C to 200 C Within 3 0 C Sa...

Страница 7: ...Alarm delay count 3 to 255 Number of occupied I O points 2 16 points 1 slot I O assignment 16 intelligent points 32 points 2 slots Default I O assignment 16 empty points 16 intelligent points Connecti...

Страница 8: ...to 800 0 to 1200 1 0 to 1000 0 to 1600 0 to 2100 1 J 0 0 to 400 0 0 0 to 500 0 0 0 to 800 0 0 1 0 0 to 1000 0 0 1 200 to 400 200 to 200 0 to 200 0 to 400 1 0 to 700 300 to 400 1 T 200 0 to 400 0 0 0 t...

Страница 9: ...them to hard impact 2 Tighten the mounting and terminal screws of the module within the following ranges Screw Location Tightening Torque Range Module mounting screw M3 screw 0 36 to 0 48N m Terminal...

Страница 10: ...or status of the Q64TCTT BW On Hardware fault including the case where no cold junction compensation resistor is connected Flicker Write data error occurrence Off Operating normally 3 ALM LED Indicate...

Страница 11: ...served 12 CJ 13 Reserved 14 CJ 15 CH3 16 CH4 17 CH3 18 CH4 2 When using Q64TCTTBW Terminal Number Signal Name 1 Reserved L1 2 CT1 L2 3 CT1 L3 4 CT2 L4 5 CT2 COM 6 CT3 Reserved 7 CT3 CH1 8 CT4 CH2 9 CT...

Страница 12: ...ircuit cables and AC control circuit Fully keep the sensors away from high voltage cables and circuits which include high frequencies e g inverter s main load circuit Not doing so can make the sensors...

Страница 13: ...CT8 CT8 CT2 CT1 CH4 CH2 CH1 Internal circuit Filter Filter Connector Always use shielded wires for cables POINT When using the heater wire break detection feature you need to make CT input channel as...

Страница 14: ...le switch setting Make the intelligent function module switch setting using the I O assignment setting of GPPW You can make setting easily by entering hexadecimal numbers into 4 digits Setting Item Sw...

Страница 15: ...0 08 112 4 41 5 0 2 98 3 86 105 4 14 2 0 08 27 4 1 08 Unit mm inch 2 Q64TCTTBW L1 L2 L3 L4 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 CT1 CT2 CT3 CT4 CT5...

Страница 16: ...arcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industries...

Отзывы: