Specifications
5. Setting Table (Factory Settings and Customer Setting Note)
Setting menu No.
Setting items
Initial content
Memo
1.1
Phase wire system
3P4(3-phase 4-wire)
1.2
Display
pattern
P04
1.2.1 Pattern
P00
―
1.3
VT/direct selection
no(No VT)
1.3.1 Direct
voltage
220/380V
1.3.2
VT secondary voltage
―
1.3.3 VT
primary
voltage
―
1.4
CT secondary current
5A
1.4.1
CT primary current
5A
1.5
Frequency
50Hz
1
1.7
Time constant for current demand
0s
2.1
Communication method selection (With ME-0040C-SS96)
CC(CC-Link)
2.2
MODBUS
®
RTU address
1
2.2.1 MODBUS
®
RTU baud rate
19.2kbps
2.2.2 MODBUS
®
RTU parity
EVEn(even)
2.2.3 MODBUS
®
RTU stop bit
1
2.3
CC-Link station number
1
2.3.1
CC-Link baud rate
156kbps
2.3.2 CC-Link
version
1.10
2
2.4
Communication
reset
oFF
3.1
Current maximum scale
5A(CT primary current)
3.1.1
Special current maximum scale
―
3.2
Voltage maximum scale
300V(±0 STEP)
3.3
Power maximum scale
4000W(±0 STEP)
3.3.1
Single / Double deflection
Single deflection
3.4
Reactive power maximum scale
4000var(±0 STEP)
3.5
Power factor scale
0.5
(
-0.5 to 1 to 0.5
)
3.6
Expanded counting
Combination I
3
3.7
Harmonics
display
oFF
4.1
Model name + option code
(Model name)
4.2
Version
display
(Version)
4.3
Back light brightness
3
4.4
Back light auto off
Auto(Auto off)
4
4.5
Display update time
0.5s
5.1
Alarm
item
1
non
5.1.1 Alarm
value
1
―
5.2
Alarm
item
2
non
5.2.1 Alarm
value
2
―
5.3
Alarm
item
3
non
5.3.1 Alarm
value
3
―
5.4
Alarm
item
4
non
5.4.1 Alarm
value
4
―
5.5
Alarm delay time
―
5.6
Alarm
cancel
method
―
5.7
Back light flickers during alarms
―
5.8
Motor start-up current masking
oFF
5.8.1
Motor start-up current threshold
―
5.8.2
Motor start-up current delay time
―
5.9
Pulse / Alarm output 1 (With ME-4210-SS96)
PULSE(Pulse output)
5.9.1
Pulse output 1: output item
Wh
5.9.2
Pulse output 1: pulse unit
0.001kWh/pulse
5.10
Pulse / Alarm output 2 (With ME-4210-SS96)
AL (Alarm output)
5.10.1
Pulse output 2: output item
―
5.10.2
Pulse output 2: pulse unit
―
5
5.11
Pulse
width
0.125s
6.1
Analog output CH1: output item
A
AVG
6.1.1
Detailed setting (1)
5A(CT primary current)
6.1.2
Detailed setting (2)
―
6.2
Analog output CH2: output item
V
AVG
(L-N)
6.2.1
Detailed setting (1)
300V(±0 STEP)
6.2.2
Detailed setting (2)
―
6.3
Analog output CH3: output item
Σ
W
6.3.1
Detailed setting (1)
4000W(±0 STEP)
6.3.2
Detailed setting (2)
Single deflection
6.4
Analog output CH4: output item
Σ
PF
6.4.1
Detailed setting (1)
0.5
(
-0.5 to 1 to 0.5
)
6.4.2
Detailed setting (2)
―
6
6.5
Analog output limit
oFF
7.1
Periodic Active energy display
oFF
(
Not displayed
)
7.1.1
Control setting for switching time segments of periodic active energy
non(Not switched)
7.3
Digital input/output status display
oFF(Not displayed)
7
7.3.1
Digital input reset method
Auto(Auto off)
8.1
Operating
time
display
oFF
8.1.1 Target for counting Operation time setting
AUX
(
Auxiliary power
)
8.1.2 Operating
time
threshold
―
8.2
Switch element information
123
8
8.3
Set IEC mode
oFF
(
Normal mode
)