3.Setting
3.2 Setting menu 1: Basic Settings (Setting the Phase Wire System, Display Pattern, VT/Direct Voltage,
CT Primary Current, etc.)
- 16 -
(2)
For other phase wire system except 3-phase 4-wire
Additional display
D
isp
la
y P
a
tt
e
rn
Cu
rre
n
t
Cu
rre
n
t D
e
m
a
n
d
Vol
tag
e
Ac
tiv
e
Pow
e
r
Power
F
ac
tor
Reac
tiv
e Pow
er
F
requenc
y
Ac
tiv
e Ener
gy
(I
m
por
te
d)
Ac
tiv
e Ener
gy
(E
x
p
or
ted)
Reac
tiv
e En
er
gy
y
(I
mpor
te
d L
A
G
)
Ac
tiv
e
Ener
gy
(I
mpor
te
d)
Ac
tiv
e
Ener
gy
(E
x
p
or
ted)
Reac
tiv
e En
er
gy
(S
p
e
cia
l)
Per
iodic
Ac
tiv
e
En
er
gy
Ha
rm
o
n
ic
Cu
rre
n
t/
Vol
tag
e
Dig
ita
l In
put/ O
utpu
t
O
per
ati
on t
im
e
P01
○
○
○
○
△
△
△
△
P02
○
○
○
○
○
○
△
△
△
△
△
P03
○
○
○
○
○
○
△
△
△
△
P04
○
○
○
○
○
○
○
○
○
△
△
△
△
△
△
P05
○
○
○
○
△
△
△
△
P06
○
○
△
△
△
△
P07
○
○
○
△
△
△
△
P08
○
○
○
○
○
△
△
△
△
△
P09
○
○
○
△
△
△
△
P10
○
○
○
○
△
△
△
△
P11
○
○
○
○
○
△
△
△
△
△
P12
○
○
○
○
○
○
△
△
△
△
△
P13
○
○
○
○
○
○
○
○
○
△
△
△
△
△
△
P00
□
□
□
□
□
□
□
□
□
□
△
△
△
△
△
△
△
Note: The following settings are required for displaying elements on an additional display.
Set the VT
When direct input (without VT)
⇒
Select no, and then press , shift to following (1).
When using VT
⇒
Select yES, and then press , shift to following (2)
1.
For 3-phase 4-wire
2.
For 3-phase 3-wire or 1-phase 2-wire
Note. VT is voltage transformers.
(1)
For direct input (without VT)Set the direct voltage.
(a)
For 3-phase 4-wire
(phase to neutral voltage / phase to phas e voltage)
(b)
For 3-phase 3-wire (2CT, 3CT) or 1-phase 2-wire
(c)
For 1-phase 3-wire
(
1N2
、
1N3
)
(phase to neutral voltage / phase to phase voltage)
③
VT / direct voltage
<W hen
①
phase wire system is set to 1-phase 3-wire>
Use only for direct input. This setting will be skipped.
SE T
SE T
yES no
110V 220V 440V
110/220V 220/440V
no yES
63.5/110V 100/173V 110/190V 220/380V 240/415V 254/440V 277/480V
SET
DISPLAY
Measurement element on
Reference
Setting item
additional display
Pages
Active energy
Exported
/reactive
energy Special(*)
Setting Menu 3 Active energy measurement
Page 22
Harmonic current/ Harmonic
voltage
Setting Menu 3 Harmonics display
Page
22
Periodic Active Energy
Setting Menu 7
Periodic Active energy display
Page 32
Digital input / output status
Setting Menu 7 Digital input / output display
Page
32
Operation time
Setting Menu 8 Operation time display
Page
33
※
When display elements does not set active energy/ reactive energy, ’P00’ of active energy/ reactive
energy on additional display does not appear.