![Mitsubishi FR-F500 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/mitsubishi/fr-f500/fr-f500_instruction-manual_1809263076.webp)
PARAMETERS
63
Func-
tion
Parameter
Number
Name
Setting Range
Minimum
Setting
Increments
Factory
Setting
〈〈〈〈
EC
Version
〉〉〉〉
Refer
To
Page:
Cust-
omer
Set-
ting
152
Zero current detection level
0 to 200.0%
0.1%
5.0%
133
C
u
rrent
det
ec
ti
on
153
Zero current detection period
0 to 1 s
0.01 s
0.5 s
133
154
Voltage reduction selection during stall
prevention operation
0, 1
1
1
77
155
RT signal activated condition
0, 10
1
0
134
156
Stall prevention operation selection
0 to 31, 100, 101
1
0
134
157
OL signal waiting time
0 to 25 s, 9999
0.1 s
0
136
Sub f
unc
ti
ons
158
AM terminal function selection
1 to 3, 5 to 6, 8,
10 to 14, 17, 21
1
1
86
Addit
ional
fu
n
cti
o
n
$
160
User group read selection
0, 1, 10, 11, 9999
1
9999
137
162
Automatic restart after instantaneous
power failure selection
0, 1
1
0
89
163
First cushion time for restart
0 to 20 s
0.1 s
0 s
89
164
First cushion voltage for restart
0 to 100%
0.1%
0%
89
A
u
to
ma
ti
c r
e
sta
rt
af
te
r ins
tant
aneous
pow
er f
a
ilure
165
Restart stall prevention operation level
0 to 150%
0.1%
120%
89
168
Sub
func
ti
ons
169
Parameters set by the manufacturer. Do not set.
170
Watt-hour meter clear
0
0
138
In
it
ial
m
onit
o
r
171
Actual operation hour meter clear
0
0
138
173
User group 1 registration
0 to 999
1
0
137
174
User group 1 deletion
0 to 999, 9999
1
0
137
175
User group 2 registration
0 to 999
1
0
137
U
s
er f
unc
ti
ons
176
User group 2 deletion
0 to 999, 9999
1
0
137
$
180
RL terminal function selection
1
0
138
$
181
RM terminal function selection
1
1
138
$
182
RH terminal function selection
1
2
138
$
183
RT terminal function selection
1
3
138
$
184
AU terminal function selection
1
4
138
$
185
JOG terminal function selection
1
5
138
$
186
CS terminal function selection
0 to 7, 10 to 14, 16,
9999
(24 Note 5)
1
6
138
$
190
RUN terminal function selection
1
0
140
$
191
SU terminal function selection
1
1
140
$
192
IPF terminal function selection
1
2
140
$
193
OL terminal function selection
1
3
140
$
194
FU terminal function selection
1
4
140
T
e
rm
inal as
s
ignm
ent
f
unc
ti
ons
$
195
A, B, C terminal function selection
0 to 5, 8, 10, 11,
13 to 19, 25, 26,
98 to 105, 108,
110, 111, 113 to 116,
125, 126, 198, 199,
9999
(40 to 48 Note 5)
1
99
140
Addit
i-
onal
fu
n
cti
o
n
199
User's initial value setting
0 to 999, 9999
1
0
142
Parameter List
4