All parameters available when the Pr. 160 "user group read selection" value is "0" are indicated below.
The parameters available when the Pr. 160 value is "9999" (Simple mode parameter) are marked in the
Parameter Number column with a circle (
$
).
Func-
tion
Parameter
Number
Name
Setting Range
Minimum
Setting
Increments
Factory
Setting
〈〈〈〈
EC
Version
〉〉〉〉
Refer
To
Page:
Cust-
omer
Set-
ting
$
0
Torque boost
0 to 30%
0.1%
6%/4%/3%
/2%
(Note 4)
66
$
1
Maximum frequency
0 to 120Hz
0.01Hz
120Hz
67
$
2
Minimum frequency
0 to 120Hz
0.01Hz
0Hz
67
$
3
Base frequency
0 to 120Hz
0.01Hz
60Hz
〈
50Hz
〉
68
$
4
Multi-speed setting (high speed)
0 to 120Hz
0.01Hz
60Hz
69
$
5
Multi-speed setting (middle speed)
0 to 120Hz
0.01Hz
30Hz
69
$
6
Multi-speed setting (low speed)
0 to 120Hz
0.01Hz
10Hz
69
$
7
Acceleration time
0 to 3600 s/
0 to 360 s
0.1 s/
0.01 s
5 s/15 s
(Note 1)
70
$
8
Deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/
0.01 s
10 s/30 s
(Note 1)
70
B
a
si
c fu
n
cti
o
n
s
$
9
Electronic thermal O/L relay
0 to 500A
0.01A
Rated
output
current
71
$
10
DC injection brake operation frequency
0 to 120Hz, 9999
0.01Hz
3Hz
72
$
11
DC injection brake operation time
0 to 10 s, 8888
0.1 s
0.5 s
72
$
12
DC injection brake voltage
0 to 30%
0.1%
4%/2%
(Note 1)
72
$
13
Starting frequency
0 to 60Hz
0.01Hz
0.5Hz
73
$
14
Load pattern selection
0, 1
1
1
74
15
Jog frequency
0 to 120Hz
0.01Hz
5Hz
75
16
Jog acceleration/deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/
0.01 s
0.5 s
75
17
MRS input selection
0,2
1
0
76
$
19
Base frequency voltage
0 to 1000V, 8888, 9999
0.1V
9999
〈
8888
〉
68
20
Acceleration/deceleration reference
frequency
1 to 120Hz
0.01Hz
60Hz
〈
50Hz
〉
70
21
Acceleration/deceleration time
increments
0,1
1
0
70
22
Stall prevention operation level
0 to 150%, 9999
0.1%
120%
77
23
Stall prevention operation level
compensation factor at double speed
0 to 200%, 9999
0.1%
9999
77
24
Multi-speed setting (speed 4)
0 to 120Hz, 9999
0.01Hz
9999
69
25
Multi-speed setting (speed 5)
0 to 120Hz, 9999
0.01Hz
9999
69
26
Multi-speed setting (speed 6)
0 to 120Hz, 9999
0.01Hz
9999
69
27
Multi-speed setting (speed 7)
0 to 120Hz, 9999
0.01Hz
9999
69
28
Multi-speed input compensation
0, 1
1
0
78
29
Acceleration/deceleration pattern
0, 1, 2, 3
1
0
79
30
Regenerative function selection
0, 2
1
0
80
31
Frequency jump 1A
0 to 120Hz, 9999
0.01Hz
9999
81
32
Frequency jump 1B
0 to 120Hz, 9999
0.01Hz
9999
81
33
Frequency jump 2A
0 to 120Hz, 9999
0.01Hz
9999
81
34
Frequency jump 2B
0 to 120Hz, 9999
0.01Hz
9999
81
35
Frequency jump 3A
0 to 120Hz, 9999
0.01Hz
9999
81
36
Frequency jump 3B
0 to 120Hz, 9999
0.01Hz
9999
81
37
Speed display
0,1 to 9998
1
0
82
38
Automatic torque boost
0 to 200
0.1%
0
83
St
andard operat
ion f
unc
ti
ons
39
Automatic torque boost operation
starting current
0 to 500
0.01A
0
83
Parameter List