25
CONNECTIONS
PRINTING
ADJUSTMENTS
PRECAUTIONS
FEA
TURES
PREP
ARA
TION
OTHERS
TROUBLE-
SHOOTING
EXTERNAL REMOTE TERMINAL 1
The image can be stored in memory by sending the remote signal through the external
remote terminal on the rear panel. When the MEM&PRN(MEMORY & PRINT) function
is set to ON, the image will be printed after being stored in memory.
•
Make out the necessary circuit to use this function by referring to the following.
2
2
2
2
2
EXTERNAL REMOTE TERMINAL SIGNAL ALLOCATION (STEREO
JACK)
Pin No.
Function
Description
1
Ground
Earth
2
MEMORY
Memory : When the signal becomes “LOW” from “HIGH”, the
image is stored in memory. (When the signal has
been “LOW” for 60ms or more, the image is stored
in memory. See page 41, 43.
3
BUSY1
Refer to the BUSY LEVEL setting of REMOTE SET in SERVICE
MENU. See page 43.
•
When the signal from BUSY terminal is received with TTL level, keep the following.
| I
OL
| = 2mA or less, | I
OH
| = 1mA or less
| I
OL
| means the current flowing into the unit at Low output, | I
OH
| means the
current flowing out of the unit at High output.
1
2
3
1
3
2
Circuit inside and pin No.
Plug pin No.
22k
Ω
22k
Ω
10k
Ω
100
Ω
DTC124EK
DC5V
22k
Ω
10k
Ω
100
Ω
DTC124EK
DC5V
22k
Ω
To VCP
From VCP
2
3
Circuit inside the VCP
MEMORY
BUSY
DMC2838