Mitsubishi AJ65S-64AD-U-H-JE Скачать руководство пользователя страница 6

 

A-5

 

 CONTENTS 

 

 

1. Overview ....................................................................................................... 1 
2. Specification  ................................................................................................. 1 

2.1 General specifications.............................................................................. 1 
2.2 Performance specifications ...................................................................... 2 
2.3 Checking hardware versions .................................................................... 3 

3. Name of Each Part ........................................................................................ 4 
4. Loading and Installation ................................................................................ 6 

4.1 Precautions when handling ...................................................................... 6 
4.2 Installation environment ........................................................................... 6 

5. Data Link Cable Wiring  ................................................................................. 7 

5.1 Connection of the CC-Link dedicated cables ........................................... 7 

6. Wiring ........................................................................................................... 8 

6.1 Wiring precautions ................................................................................... 8 
6.2 Module connection example..................................................................... 8 

7. External Dimensions...................................................................................... 9 

 

 

About Manuals 

 

The following manuals are also related to this product.  
In necessary, order them by quoting the details in the tables below. 

 

Related Manual

 

 

Manual name 

Manual No. 

(Model code) 

Analog-Digital Converter Module Type AJ65SBT-64AD 
User’s Manual 

SH-080106 

(13JR18) 

 

 

   

Compliance with the EMC and Low Voltage Directives 

 

(1) For programmable controller system 

To configure a system meeting the requirements of the EMC and Low 
Voltage Directives when incorporating the Mitsubishi programmable 
controller (EMC and Low Voltage Directives compliant) into other 
machinery or equipment, refer to the "EMC AND LOW VOLTAGE 
DIRECTIVES" chapter of the User's Manual for the CPU module used. 
The CE mark, indicating compliance with the EMC and Low Voltage 
Directives, is printed on the rating plate of the programmable controller. 

   

(2) For the product 

For the compliance of this product with the EMC and Low Voltage 
Directives, refer to the "CC-Link module" section in the "EMC AND LOW 
VOLTAGE DIRECTIVES" chapter of the User's Manual for the CPU 
module used. 

 

Содержание AJ65S-64AD-U-H-JE

Страница 1: ...the Mitsubishi general purpose programmable controller MELSEC Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL AJ65S 64A...

Страница 2: ...derate injury or property damage Under some circumstances failure to observe the precautions given under CAUTION may lead to serious consequences Observe the precautions of both levels because they ar...

Страница 3: ...z Ground the FG and FG1 terminals to the protective ground conductor dedicated to the programmable controller Failure to do so may result in malfunction z Tighten any unused terminal screws within th...

Страница 4: ...or retightening the terminal screws Failure to do so may cause the module to fail or malfunction Undertightening the terminal screws can cause short circuit or malfunction Overtightening can damage th...

Страница 5: ...tion 2 3 Sep 2006 IB NA 0800138 E Partial correction SAFETY PRECAUTIONS Chapter 3 Chapter 7 Dec 2006 IB NA 0800138 F Partial correction Chapter 6 Oct 2008 IB NA 0800138 G Partial correction SAFETY PRE...

Страница 6: ...nverter Module Type AJ65SBT 64AD User s Manual SH 080106 13JR18 Compliance with the EMC and Low Voltage Directives 1 For programmable controller system To configure a system meeting the requirements o...

Страница 7: ...2 Shock durability Conforming to JIS B 3502 IEC 61131 2 147m s2 3 times each in 3 directions Usage environment No corrosive gas Usage height 3 Less than 2000m less than 6562ft Installation area Within...

Страница 8: ...RWw 4 points each Communication cable CC Link dedicated cable Dielectric withstand voltage Between power supply communication system batch and analog input batch 500VAC 1 minute Isolation system Acros...

Страница 9: ...30 minutes after power is turned ON 1 Digit indicates digital value 2 Current value indicates value of instant input current that does not break module inner electrical resistance 2 3 Checking hardwar...

Страница 10: ...ower supply shutoff or watchdog timer error occurred RUN LED Test mode On Indicates that the SELECT SET switch is in the SET position Flashing 0 1s intervals indicate that the input range setting is n...

Страница 11: ...F OFF OFF ON 2 OFF OFF OFF OFF OFF ON OFF 3 OFF OFF OFF OFF OFF ON ON 4 OFF OFF OFF OFF ON OFF OFF 10 OFF OFF ON OFF OFF OFF OFF 11 OFF OFF ON OFF OFF OFF ON 64 ON ON OFF OFF ON OFF OFF Example To set...

Страница 12: ...l the A series programmable controller in the following environments 1 Locations where the ambient temperature is outside the range of 0 to 55 C 2 Locations where the ambient humidity is outside the r...

Страница 13: ...C Link dedicated cable between the AJ65SBT 64AD and master module as shown below DA DB DG SLD FG DA DB DG SLD FG DA DB DG SLD FG Termination resistor CC Link dedicated cable Master module side AJ65SBT...

Страница 14: ...cable However depending on the external noise conditions it may be better have a grounding externally 6 2 Module connection example V I COM SLD 500k 500k 250 V I COM SLD 500k 500k 250 FG1 CH1 4 1 Shie...

Страница 15: ...u t 1 0 5 L RUNL ERR CH1 24G DA 24V DG SLD DB AJ65SBT 64AD I V COM COM SLD TEST I V I V TEST SELECT PW RUN 2 3 4 OFFSET GAIN FG I V AG SLD COM COM FG1 SET CH3 CH2 CH1 4 STATION NO 1 B RATE 1 2 2 4 8...

Страница 16: ...s Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industri...