13
Dimensioning expansion vessel
The expansion vessel volume must be at least 5% of total water
volume in the circulation system.
HMK100 is equipped with an expansion vessel with a volume
of 10 liters.
Initial pressure and max height difference
Recommended maximum height diff erence between expansion
vessel and the highest point in the system is 5m.
The initial pressure of the pressure expansion vessel must be
dimensioned according to the maximum height (H) between
the vessel and the highest positioned radiator, see figure. An
initial pressure of 0.5 bar (5 mvp) means a maximum permitted
height diff erence of 5 m.
If the standard initial pressure in the pressure vessel is not high
enough it can be increased by filling via the valve in the
expansion vessel. The expansion vessel’s standard initial
pressure must be entered in the check list on User’s manua1.
Any change in the initial pressure affects the ability of the
expansion vessel to handle the expansion of the water.
Consult local distributor in case height diff erence exceeds 5m.
H
Recommended installation order
1. Hang indoor unit and control unit to appropriate position
and connect indoor unit and tank unit.
2. Connect indoor unit to climate system, cold and hot water
lines as well as any external heat sources. See page 14, 15.
Also see docking descriptions on page 26-28 and further
on.
3. Install refrigerant pipes according to the description on the
Installation manual for outdoor unit.
4. Connect current limiter, any centralised load control and
external contacts as well as the cable between indoor unit
and outdoor unit.
5. Connect incoming electricity to indoor unit and/or outdoor
unit. See page 34-36.
6. Follow the commissioning instructions on page 37-55.
General information for the installer
Содержание HMK60
Страница 2: ...1 2 ...
Страница 87: ...85 Technical data Electrical circuit diagram HSB60 ...
Страница 88: ...86 Technical data HMK60 RC HY FDCW60VNX A FDCW60VNX A 2 FDCW60VNX A 3 ...
Страница 89: ...87 Technical data FDCW60VNX A 2 FDCW60VNX A 3 RC HY RC HY RC HY ...
Страница 90: ...88 Technical data RC HY RC HY RC HY ...
Страница 93: ...91 Technical data sheet 3 ...
Страница 94: ...92 Technical data sheet 4 ...
Страница 97: ...95 Technical data sheet 3 ...
Страница 98: ...96 Technical data sheet 4 ...
Страница 99: ...97 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Страница 100: ...98 Technical data sheet 6 ...
Страница 101: ......
Страница 104: ...1 2 FDCW71VNX FDCW100VNX LEK LEK ...
Страница 189: ...85 Technical data Electrical circuit diagram HSB100 ...
Страница 190: ...86 Technical data HMK100 RC HY FDCW FDCW FDCW ...
Страница 191: ...87 Technical data FDCW FDCW RC HY RC HY RC HY ...
Страница 192: ...88 Technical data RC HY RC HY RC HY ...
Страница 195: ...91 Technical data sheet 3 ...
Страница 196: ...92 Technical data sheet 4 ...
Страница 199: ...95 Technical data sheet 3 ...
Страница 200: ...96 Technical data sheet 4 ...
Страница 201: ...97 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Страница 202: ...98 Technical data sheet 6 ...
Страница 203: ......
Страница 206: ......
Страница 277: ...71 Technical data Electrical circuit diagram HSB140 ...
Страница 280: ...74 Technical data sheet 3 ...
Страница 281: ...75 Technical data sheet 4 ...
Страница 284: ...78 Technical data sheet 3 ...
Страница 285: ...79 Technical data sheet 4 ...
Страница 286: ...80 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Страница 287: ...81 Technical data sheet 6 ...