13
-
PJH000Z022
(7) Duct connected (thin) -Low static pressure type (FDUT)
Model FDUT71KXE6F-E
Models
FDUT71KXE6F-E
P
an
el m
od
el (
O
pt
io
n)
R
ea
r a
ir r
et
ur
n
N
ominal
c
oo
lin
g c
apa
cit
y*
1
kW
7.
1
N
ominal
h
ea
tin
g c
apa
cit
y*
2
8.
0
P
ow
er
s
ou
rc
e
1 Phase
22
0-
24
0V 5
0H
z / 2
20
V
60
H
z
Po
w
er
c
on
sum
pt
io
n
C
oo
lin
g
kW
0.
08
0 - 0
.0
80 / 0
.0
80
H
eat
in
g
0.
07
0 - 0
.0
70 / 0
.0
70
R
unni
ng
c
ur
re
nt
C
oo
lin
g
A
0.
42 - 0
.4
2 / 0
.4
2
H
eat
in
g
0.
46 - 0
.4
6 / 0
.4
6
S
ou
nd
P
ow
er
L
ev
el
dB
(A)
H
i
:
59
S
ou
nd P
re
ss
ur
e L
ev
el
①
H
i
:
35 M
e
:
31
L
o
:
28
S
ou
nd P
re
ss
ur
e L
ev
el
②
H
i
:
41
M
e
:
37 L
o
:
32
E
xt
er
io
r d
im
ens
io
ns
H
ei
gh
t x W
id
th x D
ep
th
mm
22
0 × 1
,1
50 × 5
65
N
et
we
ig
ht
kg
31
Re
fri
ger
an
t e
qu
ip
m
en
t H
ea
t e
xc
ha
ng
er
Lo
uv
er fi
n & i
nn
er g
ro
ov
ed t
ub
in
g
R
ef
rig
era
nt
c
on
trol
E
le
ct
ro
ni
c E
xp
an
si
on V
al
ve
Ai
r h
an
dl
in
g e
qu
ip
m
en
t F
an t
yp
e & Q
'ty
C
en
tr
ifu
ga
l f
an ×
4
Fa
n m
ot
or <
st
ar
tin
g m
et
ho
d>
W
10
0 < D
ire
ct l
in
e s
ta
rt >
A
ir
flo
w
(S
tan
dar
d)
C
oo
lin
g
m
3
/min
H
i
:
16
M
e
:
13
L
o
:
9.
5
H
eat
in
g
H
i
:
16
M
e
:
13
L
o
:
9.
5
A
va
ila
bl
e s
ta
tic p
re
ss
ur
e
Pa
S
ta
nd
ar
d:
10
,M
ax
:5
0
O
ut
do
or a
ir i
nt
ak
e
P
os
si
ble
S
uc
tio
n g
ua
rd
(A
ir fi
lte
r)
, Q
'ty
P
ro
cur
e l
oc
al
ly
S
ho
ck & v
ib
ra
tio
n a
bs
or
be
r
R
ub
be
r s
le
ev
e(
fo
r f
an m
ot
or
)
In
su
la
tio
n (
no
is
e & h
ea
t)
P
ol
yu
re
than
e fo
rm
O
pe
ra
tion
c
on
trol
R
em
ot
e c
on
tro
l s
w
itc
h ( o
pt
io
n )
W
ire
d : R
C
-E
X
3A
,R
C
-E
5
W
ire
le
ss : R
C
N
-K
IT
4-
E
2
R
oom
te
m
pe
ra
tu
re
c
on
trol
Th
er
m
os
ta
t b
y e
le
ct
ro
ni
cs
S
af
et
y eq
ui
pme
nt
O
ve
rlo
ad
p
ro
tec
tion
for
fa
n mo
tor
Fr
os
t p
ro
tec
tion
th
er
mos
ta
t
Ins
ta
lla
tio
n da
ta
Li
qu
id
li
ne
R
ef
rig
er
an
t p
ip
in
g s
iz
e
G
as l
in
e
φ
9.
52 (
3/
8"
)
<
Flar
e p
ip
in
g
>
φ
15
.8
8 (
5/
8"
)
<
Flar
e p
ip
in
g
>
R
ef
rig
era
nt
R
41
0A
D
ra
in
pu
mp
B
ui
lt-
in D
ra
in p
um
p
D
ra
in
h
os
e
H
os
e C
on
ne
ct
ab
le V
P
25
(I.
D
.2
5,
O
.D
.3
2)
In
su
la
tio
n fo
r p
ip
in
g
N
ec
es
sa
ry
(b
ot
h L
iq
ui
d & G
as l
in
e)
A
cc
es
sor
ie
s
M
ou
nt
in
g k
it, D
ra
in h
os
e
E
xt
er
io
r d
im
ens
io
ns
PJ
H
000
Z0
12
E
le
ct
ric
al
w
irin
g
PJ
H
00
0Z
023
Notes (1)
The data are measured at the following conditions.
(2)
This packaged air-conditioner is manufactured and tested in conformity with the standard.
ISO-T1
"UNIT
AR
Y AIR-CONDITIONERS"
(3)
Sound Pressure Level shows the value when the supply duct of 2m and the return
duct of 1m (except the Bottom air return) are connected the unit.
(4)
Sound Pressure Level
①
:
Mike position is 1.5m below the unit,
②
:
Mike position is 1m in front and 1m below od the air supply duct.
(5)
Initial static pressure value of optional suction guard(Air filter) "UT
-FL
□
EF" is 5Pa.
(6)
Select the breaker size according to the own national standard.
Adapted t
o
Ro
HS
directive
Item
Indoor air temperature
Outdoor air temperature
Standards
External static pressure of
indoor unit (Pa)
Operation
DB
WB
DB
WB
Cooling*1
27
℃
19
℃
35
℃
24
℃
ISO-T1
10
Heating*2
20
℃
7
℃
6
℃
OPTION
Model
Specification
Remote control
Wired
RC-EX3A
PJZ000Z333
Wired
RC-E5
PJZ000Z295
Wired
RCH-E3
PJZ000Z272
Wireless
RCN-KIT4-E2
PJZ000Z323
Motion sensor
LB-KIT
PJZ000Z331
Suction guard(Air filter)
UT
-FL3EF(For71)
-
'19 • KX-T-310D