10
-
Models
FDU224KXZE1
FDU280KXZE1
N
ominal
c
oo
lin
g c
apa
cit
y*
1
kW
22.4
28.0
N
ominal
h
ea
tin
g c
apa
cit
y*
2
25.0
31.5
P
ow
er
s
ou
rc
e
1 Phase
220-240V 50Hz / 220V 60Hz
1 Phase
220-240V 50Hz / 220V 60Hz
Po
w
er
c
on
sum
pt
io
n
C
oo
lin
g
kW
1.160 - 1.200 / 1.160
1.160 - 1.200 / 1.160
H
eat
in
g
1.160 - 1.200 / 1.160
1.160 - 1.200 / 1.160
R
unni
ng
c
ur
re
nt
C
oo
lin
g
A
6.80 - 6.50 / 6.80
6.80 - 6.50 / 6.80
H
eat
in
g
6.80 - 6.50 / 6.80
6.80 - 6.50 / 6.80
Sou
nd
P
ow
er
L
ev
el
C
oo
lin
g
dB
(A)
75
75
H
eat
in
g
75
75
So
un
d P
re
ss
ur
e L
ev
el
C
oo
lin
g
P-Hi
:
52 Hi
:
50 Me
:
47 Lo
:
45
P-Hi
:
52 Hi
:
50 Me
:
47 Lo
:
45
H
eat
in
g
P-Hi
:
52 Hi
:
50 Me
:
47 Lo
:
45
P-Hi
:
52 Hi
:
50 Me
:
47 Lo
:
45
E
xt
er
io
r d
im
ens
io
ns
H
ei
gh
t x W
id
th x D
ep
th
mm
379 × 1,600 × 893
379 × 1,600 × 893
N
et
we
ig
ht
kg
89
89
Re
fri
ger
an
t e
qu
ip
m
en
t H
ea
t e
xc
ha
ng
er
Louver fin & inner grooved tubing
Louver fin & inner grooved tubing
R
ef
rig
era
nt
c
on
trol
Electronic Expansion V
alve
Electronic Expansion V
alve
Ai
r h
an
dl
in
g e
qu
ip
m
en
t F
an t
yp
e & Q
'ty
Centrifugal fan ×3
Centrifugal fan ×3
Fa
n m
ot
or <
st
ar
tin
g m
et
ho
d>
W
130 + 350 < Direct line start >
130 + 350 < Direct line start >
A
ir
flo
w
(S
tan
dar
d)
C
oo
lin
g
m
3
/min
P-Hi
:
80 Hi
:
72 Me
:
64 Lo
:
56
P-Hi
:
80 Hi
:
72 Me
:
64 Lo
:
56
H
eat
in
g
P-Hi
:
80 Hi
:
72 Me
:
64 Lo
:
56
P-Hi
:
80 Hi
:
72 Me
:
64 Lo
:
56
A
va
ila
bl
e s
ta
tic p
re
ss
ur
e
Pa
200 (at 80
m
3
/min
)
200 (at 80
m
3
/min
)
O
ut
do
or a
ir i
nt
ak
e
Possible
Possible
A
ir fi
lte
r, Q
'ty
Procure locally
Procure locally
S
ho
ck & v
ib
ra
tio
n a
bs
or
be
r
Rubber sleeve(for fan motor)
Rubber sleeve(for fan motor)
In
su
la
tio
n (
no
is
e & h
ea
t)
Polyurethane form
Polyurethane form
O
pe
ra
tion
c
on
trol
R
em
ot
e c
on
tro
l s
w
itc
h ( o
pt
io
n )
Wired : RC-EX3A,RC-E5
Wireless : RCN-KIT4-E2
Wired : RC-EX3A,RC-E5
Wireless : RCN-KIT4-E2
R
oom
te
m
pe
ra
tu
re
c
on
trol
Thermostat by electronics
Thermostat by electronics
S
af
et
y eq
ui
pme
nt
Overload protection for fan motor
Frost protection thermostat
Overload protection for fan motor
Frost protection thermostat
Ins
ta
lla
tio
n da
ta
Li
qu
id
li
ne
R
ef
rig
er
an
t p
ip
in
g s
iz
e
G
as l
in
e
φ
9.52 (3/8”)
<
Brazing
>
φ
19.05 (3/4”)
<
Brazing
>
φ
9.52 (3/8”)
<
Brazing
>
φ
22.22 (7/8”)
<
Brazing
>
R
ef
rige
ra
nt
R410A
R410A
D
ra
in
pu
mp
-
-
D
ra
in
h
os
e
Connectable with VP25
(
O.D.32)
Connectable with VP25
(
O.D.32)
In
su
la
tio
n fo
r p
ip
in
g
Necessary(both Liquid & Gas line)
Necessary(both Liquid & Gas line)
A
cc
es
sor
ie
s
Mounting kit
Mounting kit
E
xt
er
io
r d
im
ens
io
ns
PJG000Z287
PJG000Z287
E
le
ct
ric
al
w
irin
g
PJG000Z543
PJG000Z543
Notes (1)
The data are measured at the following conditions.
(2)
This packaged air-conditioner is manufactured and tested in conformity with the standard.
ISO-T1
"UNIT
AR
Y AIR-CONDITIONERS"
(3)
Sound level indicates the value in an anechoic chamber
.
During operation these value are somewhat higher due to ambient conditions.
(4)
The factory E.S.P
. setting is set within the range of 80 - 150 Pa.If SW8-4 is turned to "ON",
E.S.P
. setting range can be changed to 10 - 200 Pa.(For RC-EX3A
and RC-E5 only)
(5)
Select the breaker size according to the own national standard.
Adapted t
o
Ro
HS
directive
Item
Indoor air temperature
Outdoor air temperature
Standards
External static pressure of
indoor unit (Pa)
Operation
DB
WB
DB
WB
Cooling*1
27
℃
19
℃
35
℃
24
℃
ISO-T1
72
Heating*2
20
℃
7
℃
6
℃
PJG000Z542
Models FDU224KXZE1, 280KXZE1
OPTION
Model
Specification
Remote control
Wired
RC-EX3A
PJZ000Z333
Wired
RC-E5
PJZ000Z295
Wired
RCH-E3
PJZ000Z272
Wireless
RCN-KIT4-E2
PJZ000Z323
Motion sensor
LB-KIT
PJZ000Z331
'19 • KX-T-310D