−71−
1.
Tap the [Check of RC setting] on the menu screen.
2.
If multiple heat pump units are connected to the remote
control, a list of all heat pump unit connected. Tap the
HP unit to be displayed.
On the [Select heat pump unit] screen, up to 8 units are
displayed. If 9 or more units are connected, when tapping Next
button, the 9th and the subsequent units are displayed.
3.
Since the current setting contents are displayed, the
fi nal check of settings can be done.
Displayed item
No.
Item
Set range
1
Operation mode
Run/Stop/Pause
2
Hot water temp
From 60°C to 90°C
3
—
Out of USE
4
Storage tank Type
Unvented/Open
5
% Target HW amount
From 10% to 100%
6
HW amount setting
Usual/More/Less
7
Peak-cut %
0, 40, 60, 80%
8
Peak-cut setting
Valid/Invalid
9
Period of time off
Valid/Invalid
10
Specifi c day off
Valid/Invalid
11
Defrosting operation
Display/Hide
12
Status of HW amount
Display/Hide
13
Night tariff start
From 00:00 up to 23:50
14
Night tariff end
From 00:00 up to 23:50
15
Next service date
Day/Month/Year
16
Upper limit of HW temp.
From 70°C to 90°C
17
Application setting
HW/Heating/Hybrid
18
Preference setting
HW/Heating
19
Heating set temp
AUTO/MANUAL
If AUTO:-5~+5°C
If MANUAL:20~52°C
Notice:
Independent of application, all settings appear in this table.
How to check the remote control setting
A setting list for the current setting of remote control and heat pump unit can be checked.