−14−
■
Before use
Description of functions and contents of CO
2
heat pump water heater
The following settings can be done with this remote control.
Regarding the detailed setting methods, please check each function mentioning in reference page.
Setting and display item
Contents
Reference page
Run
The heat pump unit can be started operation.
The heat pump unit is operated according to the set operation
pattern.
Page 21
Pause
The heat pump unit can be paused operation.
The set operation pattern becomes invalid and the heat pump
unit does not start hot water storage operation.
*
Protection operation of heat pump unit (Anti-freeze protection
operation) may start.
Page 21
Schedule setting
Setting of weekly
operation pattern
Set the operation pattern on the day of a week.
■
Maximum 8 patterns in a day can be set.
Page 24
Setting of day off
①
Every week
②
Specific period of
time
③
Specific day
On the day that the hot water storage operation is no necessary
such as holiday and day off, it can be set [Day off].
①
Set the day in every week [Day off].
②
Set the [Start day] and the [End day], and set [Day off]
through this period.
③
Set the specific day, and set it [Day off].
Page 27
Peak-cut timer
Set the [Start time] and [End time] of the operation to limit the
capacity and saving rate of capacity.
■
Maximum 4 patterns in a day can be set.
■
From 0% to 80% (at 20% intervals) of the saving rate of
capacity can be selected.
*
The clock setting is required.
Page 29
Checking of operation
pattern
The current operation pattern can be checked.
Page 32
Operation to fill up
The heat pump unit is operated until the hot water storage
unit is filled with hot water up to 100%.
Page 33
Setting of hot water temp
Hot water temp can be set.
Page 22
Setting of hot water amount
Hot water storage amount can be increased or decreased
uniformly.
Page 34
Display usage of hot water amount
The usage of hot water amount for the selected heat pump
unit is displayed.
■
The hot water amount on the last previous day and the
present day is displayed. (for maximum 48 hours)
Page 35
Display of
operation mode
Display contents on RC
Page 35
· Now stopping
The heat pump unit is stopping
The heat pump unit does not start operation
· It makes a Pause by
switch Run/Pause,
· Paused by “Day
OFF” setting
The heat pump unit is stopping by operating [Run/Pause]
switch or by the “Day off” setting.
The heat pump unit does not start operation but it may start
protection operation.
· It is in operation by
standby
Since the current hot water amount exceeds the target amount,
it makes the heat pump unit standby.
· It is in operation to
top up
The heat pump unit is in operation to top up.
· It is in operation to
fill up
The heat pump unit is in operation to fill up.
· In operation for anti-
freezing
In order to prevent water in the pipe from freezing, the water
pump is operating.