![Mitsubishi Electronic FR-E860 Series Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/mitsubishi-electronic/fr-e860-series/fr-e860-series_instruction-manual_1811926033.webp)
32
2. Installation and Wiring
2.4 Terminal connection diagrams
Ethernet model
*1
Remove the jumper between P1 and P/+ to connect the DC reactor.
*2
The function of these terminals can be changed using the Input terminal function selection (
Pr.178 to Pr.179
). (Refer to the FR-E800 Instruction
Manual (Function).)
*3
The initial setting varies depending on the specification.
*4
Terminal input specifications can be changed by analog input specification switchover (
Pr.73, Pr.267
). To input voltage, set the voltage/current
input selection switch to "V". To input current, set the switch to "I". The initial setting varies depending on the specification. (Refer to the FR-E800
Instruction Manual (Function).)
*5
It is recommended to use 2 W 1 k
Ω
when the frequency setting signal is changed frequently.
*6
The function of these terminals can be changed using the
Pr.192 ABC terminal function selection
.
Control circuit terminal
Main circuit terminal
Sink logic
Motor
Earth (Ground)
Three-phase
AC power
supply
MCCB
MC
Earth
(Ground)
Main circuit
Control circuit
Earth
(Ground)
R/L1
P1
P/+
PR N/-
S/L2
T/L3
U
V
W
Jumper
DC reactor
R
Forward
rotation start
Reverse
rotation start
Control input signals (No voltage input allowed)
Contact input common
Frequency setting signals (Analog)
Frequency
setting
potentiometer
1/2W1kΩ
Terminal 4 input
(Current input)
(+)
(-)
Safety stop input common
24VDC power supply(Common for
external power supply transistor)
Safety stop input (Channel 1)
Shorting wire
Safety stop input (Channel 2)
2 0 to 5VDC
10(+5V)
2
3
1
4 4 to 20mADC
5(Analog common)
Connector for
plug-in option connection
Option connector
USB mini B
connector
Ethernet
connector
Ethernet
connector
0 to 5VDC
0 to 10VDC
Voltage/current
input switch
0 to 5VDC
0 to 20mADC
4
2
I
V
PC
S1
S2
Output
shutoff
circuit
SD
SOURCE
24V
SINK
SINK
SOURCE
DI1
DI0
A
B
C
Safety stop signal
Safety monitor output
Safety monitor output common
SO
SOC
Relay output
Relay output
(Fault output)
M